5-37
Cisco 600 Series Installation and Operation Guide
78-11190-01
Chapter 5
Configuration Procedures for the Cisco 67x CPE Devices
Configure Line Coding (Cisco 677 and Cisco 678 only)
cbos#
set interface wan0 retrain
cbos#
show interface wan0
wan0 ADSL Physical Port
Line Trained
Actual Configuration:
Overhead Framing
: 3
Trellis Coding: Disabled
Standard Compliance:
G.lite
Downstream Data Rate: 1536 Kbps
Upstream Data Rate: 512 Kbps
Interleave S Downstream: 4
Interleave D Downstream: 16
Interleave R Downstream: 4
Interleave S Upstream: 8
Interleave D Upstream: 8
Interleave R Upstream: 8
Modem Microcode: G96
DSP version: 0
Operating State: Showtime/Data Mode
Configured:
Echo Cancellation: Disabled
Overhead Framing: 3
Coding Gain: Auto
TX Power Attenuation: 0dB
Trellis Coding: Enabled
Bit Swapping: Disabled
Standard Compliance: G.lite
Remote Standard Compliance:T1.413
Tx Start Bin: 0x6
Tx End Bin: 0x1f
Data Interface: Utopia L1
Status:
Local SNR Margin: 28.0dB
Local Coding Gain: 1.5dB
Local Transmit Power: 12.3dB
Local Attenuation: 22.5dB
Remote Attenuation: 21.5dB
Local Counters:
Interleaved RS Corrected Bytes: 0
Interleaved Symbols with CRC Errors: 0
No Cell Delineation Interleaved: 0
Out of Cell Delineation Interleaved: 0
Header Error Check Counter Interleaved:0
Count of Severely Errored Frames: 0
Count of Loss of Signal Frames: 0
Remote Counters:
Interleaved RS Corrected Bytes: 0