A-34
Catalyst 6500 Series Switches Installation Guide
OL-5781-08
Appendix A Power Supply Specifications
2700 W AC-Input and DC-Input Power Supplies
Table A-23
2700 W AC-Input and DC-Input Power Supply LEDs
LED
Meaning
INPUT 1 OK
INPUT 2 OK (DC-input
power supply only)
AC-input power supplies:
•
Green—Source AC voltage is OK. (Input voltage is 85 VAC or
greater.)
•
Off—Source AC voltage falls below 70 VAC, is not present, or the
power supply is turned off.
DC-input power supplies:
•
Green—Source DC is OK. (Input voltage is –40.5 VDC or greater.)
•
Off—Source DC voltage falls below –33 VDC, is not present, or the
power supply is turned off.
FAN OK
•
Green—Power supply fan is operating properly.
•
Off—Power supply fan failure is detected.
OUTPUT FAIL
•
Red—Problem with one or more of the DC-output voltages of the
power supply.
•
Off—DC-output voltages within acceptable margins.
Note
For proper operation of the OUTPUT FAIL LED, systems with
single power supplies must be configured with a minimum of
one fan tray and one supervisor engine. Systems with dual power
supplies must have a minimum configuration of one fan tray, one
supervisor engine, and one additional module. Failure to meet
these minimum configuration requirements can cause a false
power supply output fail signal.
Содержание 6500 - Catalyst Series 10 Gigabit EN Interface Module Expansion
Страница 4: ......
Страница 18: ...xviii Catalyst 6500 Series Switches Installation Guide OL 5781 08 Preface Conventions ...
Страница 444: ...D 16 Catalyst 6500 Series Switches Installation Guide OL 5781 08 Appendix D Chassis and Module Power and Heat Values ...
Страница 452: ...E 8 Catalyst 6500 Series Switches Installation Guide OL 5781 08 Appendix E Troubleshooting Contacting Customer Service ...