background image

 

12

Cisco 5915 Embedded Services Router Hardware Technical Guide

OL-24796-01

Product Specifications

For integrators planning to use the conduction-cooled Cisco 5915 ESR, mounting holes are in the 
thermal plate. These mounting holes are used to hold an I/O board or flex circuit to the Cisco 5915 ESR. 
The mounting hole size is 0.125 Inches (diameter). Four 4-40 pan head screws are required.

For integrators planning to use the air cooled Cisco 5915 ESR, mounting holes are provided in the 
Printed Circuit Board (PCB) which can be used, along with a custom "L bracket" to hold an I/O board 
or flex circuit to the Cisco 5915 ESR.

Note

Mounting hole and screw sizes for air cooled Cisco 5915 ESR depend on the system or environment in 
which the air-cooled cards are used.

Note

When you connect routed ports of the Cisco 5915 ESR to routed ports on a neighboring device and 
autonegotiation is disabled on both sides of the connection, a crossover cable may be necessary 
(depending on the capabilities of the neighboring device). If autonegotiation is enabled, any type of cable 
connection can be used.

Product Specifications

Table 7

 lists the technical specifications for Cisco 5915 ESR.

Table 7

Cisco 5915 ESR Product Specifications 

Cisco 5915 ESR Feature

Feature Description

Hardware Encryption

Onboard hardware encryption processor supporting IP Security 
(IPsec)

Secure Sockets Layer with transparent LAN services 
(SSL/TLS)

Triple Digital Encryption Standard (3DES)

Advanced Encryption Standard (AES)

Internet Key Exchange (IKE)

Message Digest - MD5 & SHA along with HMAC

Memory

DRAM

512 MB

Flash Memory

256 MB

Interface Support

Fast Ethernet

Two routed 10/100 copper ethernet ports

Three switched 10/100 copper ethernet ports

Router Console Port

One RS-232 console port supporting modem flow control signaling.

Environmental

Industrial-grade components 

–40° F to +185° F (–40° C to +85°C) component local ambient 
temperature ranges

Содержание 5915

Страница 1: ...g sections About This Guide page 1 Audience page 2 Related Documentation page 2 Conventions page 2 Introduction page 3 Cisco 5915 ESR Conduction Cooled Card page 4 Installing the Cisco 5915 ESR Conduction Cooled Card page 6 Removing the Cisco 5915 ESR Conduction Cooled Card page 7 Cisco 5915 ESR Air Cooled Card page 7 Cisco 5915 ESR LED Definitions page 9 Factory Default page 10 Temperature Out of...

Страница 2: ...ndex Additional documentation for the Cisco 5900 ESR Series can be found at www cisco com go 5900 Conventions This document uses the following typographical conventions Convention Description boldface font Commands command options and keywords are in boldface italic font Command arguments for which you supply values are in italics Command elements in square brackets are optional x y z Alternative ...

Страница 3: ...ed small form factor router intended for mobile and vehicle networking applications Like its predecessor Mobile Access Router Card used in the Cisco 3200 Rugged Integrated Services Router ISR the Cisco 5915 ESR is targeted particularly at transportation customers especially heavy light and metro rail and global defense organizations The Cisco 5915 ESR is a high performance router designed for hars...

Страница 4: ... Cisco 5915 Embedded Services Router Bottom Side View Cisco 5915 ESR Conduction Cooled Card The Cisco 5915 ESR conduction cooled card Figure 3 and Figure 4 operates at a temperature range of 40ºC to 85ºC rail temperature Thermal plates conduct the heat away from the components to the enclosure rails through the wedge locks The conduction cooling removes the need for internal fans ...

Страница 5: ...ide OL 24796 01 Cisco 5915 ESR Conduction Cooled Card Figure 3 Cisco 5915 ESR Conduction Cooled Card Bottom View Table 1 Cisco 5915 ESR Conduction Cooled Card Bottom View Markings 1 PCI Connector 3 Edge Finger Main 2 Edge Finger Auxiliary 4 Thermal Plate Bottom ...

Страница 6: ... procedures wear a grounding wrist strap to avoid ESD damage to the Cisco 5915 ESR conduction cooled card Some platforms have an ESD connector for attaching the wrist strap Do not directly touch the edge finger or PCI connector pins with your hand or any metal tool to avoid component failure Table 2 Cisco 5915 ESR Conduction Cooled Card Top View Markings 1 PCI Connector 4 Wedge Lock 2 Wedge Lock 5...

Страница 7: ...ng a hex screwdriver and complete seven 7 counter clockwise turns Caution Do not loosen the wedge locks past seven 7 counter clockwise turns for removal Doing so could cause the wedge lock to fall off the card into the chassis Step 2 Carefully remove the Cisco 5915 ESR conduction cooled card out of the conduction cooled chassis Cisco 5915 ESR Air Cooled Card The Cisco 5915 ESR air cooled card oper...

Страница 8: ... OL 24796 01 Cisco 5915 ESR Air Cooled Card Figure 5 Cisco 5915 ESR Air Cooled Card Bottom View Figure 6 Cisco 5915 ESR Air Cooled Card Top View Table 3 Cisco 5915 ESR Air Cooled Card Bottom View Markings 1 PCI Connector 3 Edge Finger Main 2 Edge Finger Auxiliary ...

Страница 9: ... LED is connected to ground Figure 7 Table 4 Cisco 5915 ESR Air Cooled Card Top View Markings 1 Edge Finger Main 3 PCI Connector 2 Edge Finger Auxiliary Table 5 LED Definitions LED names Activity System LED OFF No power BLINKING Boot up phase or in ROMMON monitor mode SOLID Steady state IOS load completed and running Temperature LED OFF Thermal reading is within the range BLINKING Thermal reading ...

Страница 10: ...gles blinks for 0 5 seconds then deasserts turns off After the process is completed the LED_CLEAR signal asserts turns on and the Table 6 Settings and Completion Time for Factory Default Capability Options Option Target Typical Completion Time erase flash This option erases the Flash file system that includes the IOS images and scrubs the main memory to ensure all code information is removed 6 25 ...

Страница 11: ...ESR can be deployed in a variety of applications and physical formats I O signal access is provided via edge fingers The edge fingers are intended to connect with standard commercially available PCI Express connectors Typically integrators use a custom wiring board to access the I O signals For instance one side of the wiring board is populated with the PCI Express connectors while the other side ...

Страница 12: ...g device and autonegotiation is disabled on both sides of the connection a crossover cable may be necessary depending on the capabilities of the neighboring device If autonegotiation is enabled any type of cable connection can be used Product Specifications Table 7 lists the technical specifications for Cisco 5915 ESR Table 7 Cisco 5915 ESR Product Specifications Cisco 5915 ESR Feature Feature Des...

Страница 13: ...and conduction cooled boards EMI EMC Conforms to CISPR 22 FCC Part15B Class A limits The system integrator is responsible for completing the necessary Safety EMC testing and labelling the final product sold to the customer Hardware Specifications Power requirements profile 5 VDC from PCI connector 5V Max theoretical 4 26W Typical rail temperature 25C 3 00W1 Typical rail temperature 85C 3 10W1 InRu...

Страница 14: ...ons are in accordance with manufacturing specifications and are the most detailed information that can be disseminated Weight Conduction cooled 290 grams Air cooled 75 grams Mean Time Before Failure MTBF 2 Air cooled card and Conduction cooled card Ground Fixed Controlled 844 000 hours Air cooled card and Conduction cooled card Ground Mobile 140 000 hours 1 Based on lab testing with traffic on all...

Страница 15: ... Guide OL 24796 01 Hardware Information Figure 9 Layout of the CIsco 5915 ESR Conduction Cooled Card Cisco 5915 Air Cooled Card Layout and Dimensions Figure 10 shows the layout and dimensions of the Cisco 5915 ESR air cooled card The dimensions are in inches ...

Страница 16: ...PCIe standard The edge fingers consist of 64 pins in the main connector Table 8 The signal interfaces are routed through these pins The following part numbers are the mating connectors solderable EDGE Connector Main Molex 87715 9106 EDGE Connector Aux Molex 87715 9006 Note All signals on the Auxiliary edge fingers are reserved Leave these signals unconnected Table 8 Edge Finger Main Connector Mapp...

Страница 17: ...ed 18 No Contact Physical spacing No Contact Physical spacing 19 No Contact Physical spacing No Contact Physical spacing 20 No Contact Physical spacing No Contact Physical spacing 21 No Contact Physical spacing No Contact Physical spacing 22 No Contact Physical spacing No Contact Physical spacing 23 ETH_FE0 2_TX ETH_FE0 2_RX 24 ETH_FE0 2_TX ETH_FE0 2_RX 25 ETH_FE0 3_TX ETH_FE0 3_RX 26 ETH_FE0 3_TX...

Страница 18: ...because it is not used The only electrical connections to the PCI connector are 5V 3 3V and GND Note The Cisco 5915 ESR uses the variant of the PCI bus stacking connector which is keyed on pin D30 Table 9 PCI Bus Signal Assignments Pin A B C D 1 GND 5V 2 5V 3 GND 4 GND 5 GND GND 6 7 GND 8 3 3V 3 3V 9 GND 10 GND 3 3V 11 3 3V GND 12 3 3V GND 13 GND 3 3V 14 GND 3 3V 15 3 3V GND 16 GND 17 3 3V 3 3V 18...

Страница 19: ... New in Cisco Product Documentation as an RSS feed and set content to be delivered directly to your desktop using a reader application The RSS feeds are a free service Cisco currently supports RSS Version 2 0 Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and or its affiliates in the U S and other countries To view a list of Cisco trademarks go to this URL www cisco com ...

Страница 20: ...20 Cisco 5915 Embedded Services Router Hardware Technical Guide OL 24796 01 Obtaining Documentation and Submitting a Service Request ...

Отзывы: