Catalyst 4500 E-Series Switches Installation Guide
OL-13972-02
Appendix A Power Supply Specifications
6000 W AC-Input Power Supply
Remote Power Cycling Feature
The 6000 W AC-input power supply is equipped with a remote power cycling feature that allows you to
remotely turn on or turn off the power supply through an external relay controller box.
Figure A-9
shows
a typical remote power on/off setup. A three-position terminal block, located on the lower right quadrant
of the power supply faceplate, provides the interface to the external relay controller box. (See
Figure A-9
.)
Figure A-9
Remote Power On/Off Feature Components
Terminal Block
The terminal block has four contacts lV, IN, GND, and FB. Two control wires from an external
relay controller box attach to V and IN or IN and GND. +V and IN are used when the relay
controller box contains a normally-open (NO) type of relay. IN and GND are used when using an RS-232
interface.
Israel
CAB-S132-C19-ISRL=
14 ft (4.3 m)
16 A, 250 VAC
SI 16S3
Brazil
CAB-EL224-C19-BR=
8 ft (2.9 m)
10 A, 250 VAC
NBR 14136
UPS 220V
CAB-C19-CBN
9 ft (2.74 m)
20 A, 250 VAC
IEC-60320-C20
Table A-33
6000 W AC-Input Power Supply Power Cords (continued)
Locale
Power Cord Part Number
Length
Cordset Rating
AC Source Plug Type
130922
275665
130923
274632
Remote
power on/off
terminal block
Ferrite
bead
Relay controller
6000 Watt power supply
Network
Relay
controller
power