2-33
Cisco ONS 15530 Hardware Installation Guide
OL-7706-01
Chapter 2 Installing the Cisco ONS 15530
Powering Up the Shelf
Step 4
Connect the negative DC power lead from the external power source to the negative (–) DC terminal
(see
Figure 2-25
).
Step 5
If you are installing redundant DC power, repeat
Step 3
and
Step 4
on the second power supply,
connecting to a second external power source.
Connecting AC-Input Power
The Cisco ONS 15530 can be powered directly from the facility VAC input through the
Cisco ONS 15530 120–240 VAC power supply (see
Figure 2-26
). A retention clip secures the power
cord to the power supply.
Figure 2-26
120–240 VAC Power Supply
Note
The AC power cord that connects to the Cisco ONS 15530 120–240 VAC power supply power cord and
then to the building AC is not shipped with the Cisco ONS 15530. You must order this power cord
separately.
The AC-input power supply differ in plug type; make sure you have the correct style for your site (see
Figure 2-27
and
Table 2-1
.) All AC-input power supply power cords measure 8 feet (2.5 m). We
recommend that you:
•
Install an uninterruptable power source where possible.
•
Install proper grounding to avoid damage from lightening and power surges (see the
“Grounding the
Shelf” section on page 2-14
).
1
Power cord
2
Retention clip
99265
FASTENERS MUST BE
FULLY ENGAGED PRIOR TO
OPERATING THE POWER SUPPLY
100-240V
~
8.0- 3.5A
50-60 HZ
GOOD
FAIL
1
2