Normal Mode
2400H Fixed Cycle
(77ms)
1st Image
Normal Mode
-
External Trigger IN
Exposure OUT
Camera
Video Out
FVAL OUT
312H Fixed Delay
(10ms)
SOPT Mode Setting
Address: 062 Data: 000
· · ·
45M Mode
SOPT Standby Setting
Address: 063 Data: 001
· · · External Trigger
SOPT Standby Setting
Address : 063 Data: 000
· · · Standby off
With receiving software trigger commands, trigger will be generated
automatically in the camera to output SOPT images.
When a trigger is input during SOPT operation, the trigger shall be ignored.
SOPT 45M Mode (shifting 9 times) (Example)
2nd Image
8th Image
9th Image
11.3.
To operate SOPT with software trigger (45M Mode)
(1)
With 1 trigger input, 9 images can be output at 45M mode and 4 images can be output at 5M 3CCD
mode.
(2)
Partial scan mode can not be used at SOPT Mode.
(3)
Pulse width trigger mode can not be used at SOPT Mode. Shutter values should be set at the
address 002.
11.4.
To opererate SPOT with external trigger signals (45M Mode)
(1)
With 1 trigger input, 9 images can be output at 45M mode and 4 images can be output at 5M 3CCD
mode.
(2)
Partial scan mode can not be used at SOPT Mode.
(3)
Pulse width trigger mode can not be used at SOPT Mode. Shutter values should be set at the
address 002.