VCC-FM60FV19CL
Rev.
900-714-31-00
©2011 CIS Corporation. All rights reserved.
15
LVAL Output
Video Output
FVAL Output
DVAL Output
12H
TTL IN(a)
(CCD Read
Out Signal)
1
9
22
2079
2058H
2070H
(Trigger Input)
Trigger IN
(Sub Pulse)
(CCD Read Out Signal)
Exposure Output
a
1203
CLK
81
CLK
a
b
21.40μs
CLK60MHz
nHD × 32.07μs+27.73μs
Delay(Fixed)
Exposure Time
b
7.3.
Fixed Trigger Shutter Mode
□
Trigger operation is CLK Sync. V-Sync Reset. The delay time from detecting trigger edge in the camera
to starting exposure is 21.40
μ
s.
□
Triggers can be accepted even when outputting video signals. However, shutter timing to start the next
video output prior to the completion of video transmission for the prior video output signals can not be
accepted. Trigger input while outputting video signals should be synchronized with the down edge of
camera LVAL output.
□
Trigger input during exposure time should be ignored. (Refer to the below G.).
(E)
(B)
(B)
(F
)
Trigger Invalid
(E)
(F)
(F)
(G)
X
Standard Trigger Mode
Video Output
Trigger IN
DVAL Output
Exposure Output
Exposure Time
(
Register Set Value )
Exposure Time
(Register Set Value )
(Exposure Time)
X