VCC-FM60FV19CL
Rev.
900-714-31-00
©2011 CIS Corporation. All rights reserved.
17
FVAL Output
(Normal Scan)
9 H
Video Output
(Normal Scan)
2079 H
VIDEO Output
(Partial Scan)
FVAL Output
(Partial Scan)
9 H
12 H
Total Line(Address 021&022) + 1H
2058 H
Y Offset
12H + Starting Position
(Address016&017)
Effective Line
(Address 019&020)×3+3H
High Speed
Transmit Term
High Speed
Transmit Term
8.
Partial Scan Mode Details
At Partial Scan Mode, both starting position and width of capturing can be set by 3H.
Reading out position register (Address 016&017)
: 0(0 H)
~
685(2055 H)
3 H/step
Effective line register (Address 019&020) : 0(3 H)
~
685(2058 H) 3 H/step
Total line resister (Address 021&022) : 706 H + (Effective line register × 2) + 2 (Read Only)
(Note)
Reading out position and effective lines should meet the following conditions.
Reading out position re Effective line register =< 685
If the above conditions are not met, the value, 685 – reading out position register
is to be set to the effective lines register.
<Setting Example 1>
Condition: Reading out position register (Address 016&017)
= 000
Effective Line Register
(Address 019&020)
Effective Lines
Total Line Register
+
1 H
Frame Rate
0
3 H
709 H
44 fps
・
・
・
・
159
480 H
1027 H
30 fps
・
・
・
・
255
768 H
1219 H
26 fps
・
・
・
・
341
1026 H
1391 H
22 fps
・
・
・
・
399
1200 H
1507 H
21 fps
・
・
・
・
685 2058
H
2079 H
15 fps