Camera Link  I/F

 

5.01M Pixels  CMOS  B/W Camera 

VCC-5CL4M 

   

 

 

Product Specifications 

& Operational Manual 

 

 

 
 
 
 
 
 
 
 
 
 

CIS Corporation 

Содержание VCC-5CL4M

Страница 1: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved Camera Link I F 5 01M Pixels CMOS B W Camera VCC 5CL4M Product Specifications Operational Manual CIS Corporation...

Страница 2: ...Horizontal Synchronous Signals Timing 2Tap Base configuration mode 15 7 2 Vertical Synchronous Signals Timing 2Tap Base configuration mode 15 7 3 Horizontal Synchronous Signals Timing 3Tap Base confi...

Страница 3: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 2 16 CMOS Pixel Defect 35 17 Product Support 35 18 Ordering Information 35...

Страница 4: ...ht source sun etc and when camera is not in use put the lens cap on Follow the instructions in Chapter 6 External connector pin assignment for connecting the camera Improper connection may cause damag...

Страница 5: ...Pulse width trigger shutter mode Full frame rate and video output are as below 3 System Configuration 3 1 Camera Camera VCC 5CL4M 3 2 Optional Accessories M42 C lens mount conversion ring M42 F lens m...

Страница 6: ...8bit 10bit B W output 7 Sensitivity F4 400lx Shutter speed 1 58s OFF Gain 0dB 4tap8bit configuration mode 8 Minimum illumination F1 4 0 19lx Shutter speed 1 58s OFF Gain 36dB 4tap8bit configuration mo...

Страница 7: ...Video output data Effective video output 2448 H 2048 V At full frame scan mode 2 Sync signal input and output LVAL No 6 pin 12pins circular connector LVTTL output FVAL No 7 pin EXPOSURE No 9 pin DVAL...

Страница 8: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 7 4 3 CMOS Spectral Response The lens characteristics and illuminant characteristics are excluded...

Страница 9: ...se configuration mode 28fps 2 3Tap Base configuration mode 42fps 3 4Tap Medium configuration mode 57 fps 4 8Tap Full 8tap10bit configuration mode 114fps D D 2048lines 2448pixels 1 2 D D D D 2048line 2...

Страница 10: ...on cannot be operative at CLK sync mode This mode is effective to avoid hunting at high speed shutter operation 6 0 H sync mode Trigger is taken with H sync A trigger during outputting images can be i...

Страница 11: ...e time with s approximate value Refer to the manual shutter settings of FAST trigger mode CLK sync mode Vertical partial lump settings 50 3 parameters The 1st parameter Partial number 0 7 The 2nd para...

Страница 12: ...te the list of data at ex factory and the registered data by the user 2 at setup Indicate only the list of the registered data by the user 3 at setup Indicate the registered number of the defect pixel...

Страница 13: ...ap Base configuration mode 16 633 s 3Tap Base configuration mode 11 111 s 4Tap Medium configuration mode 8 350 s 8Tap configuration mode 4 175 s The minimum setting value shall be 1 and the maximum se...

Страница 14: ...ed 13 6 External Connector Pin Assignment 6 1 12pins Circular Connector HR10 10R 12PA 73 HIROSE or equivalent Pin No Description 1 GND 2 Power input DC 12V 3 GND 4 NC 5 GND 6 LVAL output 7 FVAL output...

Страница 15: ...Please make sure that power is OFF when changing the switch settings If the switch setting was changed while power is ON it may cause malfunction or damages to the camera Pin No Description Pin No De...

Страница 16: ...k Port B Camera Link Port A 1 3 5 7 2 4 6 8 2440 2442 2445 2447 2441 2443 2446 2448 1 2 Video Out 2 4 4 7 2 4 4 8 Camera Link CLK 74 25MHz 7 2 Vertical Synchronous Signals Timing 2Tap Base configurati...

Страница 17: ...era Link Port A 1 3 4 6 2 5 2443 2445 2446 2448 2444 2447 1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 5 6 2 4 4 3 2 4 4 4 Camera Link CLK 74 25MHz 7 4 Vertical Synchronous Signals Timing 3Tap Ba...

Страница 18: ...k Port B Camera Link Port A 1 3 5 7 2 4 6 8 2441 2443 2445 2447 2442 2444 2446 2448 1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 Camera Link CLK 74 25MHz 7 6 Vertical Synchronous Signals Timing 4...

Страница 19: ...1 2 Video Out 2 4 4 7 2 4 4 8 3 4 2 4 4 5 2 4 4 6 Camera Link Port H Camera Link Port G Camera Link Port F Camera Link Port E 5 7 6 8 2445 2447 2446 2448 5 6 7 8 2 4 4 3 2 4 4 4 2 4 4 1 2 4 4 2 Camer...

Страница 20: ...ode Time for 1 line 2Tap Base configuration mode 16 633 s 3Tap Base configuration mode 11 111 s 4Tap Medium configuration mode 8 350 s 8Tap configuration mode 4 175 s There is an exposure time period...

Страница 21: ...5 s Input more than 1 s width pulse as a trigger There is an exposure time period for approx 13 73 s at the edge right after exposure output Trigger input while outputting images cannot be accepted Tr...

Страница 22: ...exposure time would change so that flicker might be noticeable in the image especially when high speed shutter is set This flicker sometimes can be eliminated when fixed trigger shutter mode is used...

Страница 23: ...pulse width of the trigger signals Trigger operation is CLK sync and V sync restart system The delay time Exposure Time Delay from detecting trigger edge in the camera to starting exposure is approx...

Страница 24: ...Effective Line Exposure Out 2 0 4 8 1 TRIG IN LVAL Out FVAL Out Video Out DVAL Out Effective Line Trigger input ignore period Exposure Time Exposure Time Delay Exposure Time Delay A TRIG IN Exposure...

Страница 25: ...n Effective Lines 3 Partial Scan Effective Lines 1 Partial Scan Setting Sequence of Video Output Partial area 1 Partial area 2 Partial area 3 When setting several partial scan areas please set the sta...

Страница 26: ...1070 84 1 1070 111 9 1070 223 8 1070 Vertical UXGA equivalent 1200 H fps H fps H fps H fps H 48 3 1246 72 2 1246 96 1 1246 192 2 1246 2048 Max 2048 H fps H fps H fps H Fps H Full frame 28 7 2094 43 0...

Страница 27: ...d in capital letters Separate between a command and a parameter by one space From the head of input character to the linefeed code r or n is analyzed as one command With 0x the parameter shall be anal...

Страница 28: ...ned value r n Linefeed Returned value sp Prompt Space 5 r or n Make sure to input to indicate the end of the command 6 Initial settings Input INIT to restore to the initial settings Not saved at this...

Страница 29: ...are different at normal mode and at vertical flip mode The number of data registerable by users is 128 Note Up to 32 points per CH CH Channel Images are processed by 4CH interleaves 0 0 1 0 2 0 3 0 0...

Страница 30: ...ld not be deleted Additional registration of defected pixels by users Address 101 This is the function to register any defected pixels specifying its coordinate There are 2 parameters as commands The...

Страница 31: ...ered by the user P Defects added by the user Parameter 3 Indicates the number of the registered defected pixels per CH Data at Ex factory Data registered by the user Parameter 4 Indicates the number o...

Страница 32: ...SU sp 200 sp Write Address sp Data Returned value r n Returned value sp 2 Continuous data writing The maximum 4 of 1 byte 0 255 or 0x00 0xFF data can be set with space partitions If more numbers than...

Страница 33: ...ity 4 0 Positive Trigger input 5 0 Camera Link CC1 FAST trigger mode selection 6 0 H sync mode Test pattern output 7 0 OFF Cursor indication 8 0 OFF Horizontal flip of the output image 11 0 Normal Ver...

Страница 34: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 33 13 Sensor Optical Axis Accuracy...

Страница 35: ...VCC 5CL4M Rev 905 0060 04 2016 CIS Corporation All rights reserved 34 14 Dimensions...