Value
Description
Stop transaction
when EV
unplugged
YES:
Charge Transaction stops when the cable is disconnected from
the EV
NO:
Charge Transaction does not stop when the cable is disconnect-
ed from the EV; furthermore, if it is reconnected energy transfer is
allowed again. It is required for the user to present the identifier in
order to stop the Charge Transaction.
Unlock CP
side when EV
unplugged
YES:
Charge Point unlocks the connector when the cable is discon-
nected from the EV
NO:
Charge Point keeps the connector locked when the cable is dis-
connected from the EV, it is required for the user to present the iden-
tifier in order to unlock the connector
Supported profiles
List of supported profiles on the Charge Point
NOTE:
this field is for information purposes, it cannot be modified.
Maximum number
of configuration
Keys
Maximum number of requested configuration keys that can be re-
quested by the Central System.
NOTE:
this field is for information purposes, it cannot be modified.
Heartbeat interval
Number of seconds between Heartbeats.
NOTE:
setting this value to 0 disables the Heartbeat.
WebSocket ping
interval
Number of seconds between Pings.
NOTE:
setting this value to 0 disables the Websocket Ping/Pong.
Metervalue (select
one or more)
List of supported values used in the MeterValue.
NOTE:
hold 'Ctrl' key in order to select more than one Measurand.
Transaction
message attempts
How many times the Charge Point should try to send a request to the
Central System.
Содержание Wallbox ePark
Страница 1: ...Wallbox ePark INSTRUCTION MANUAL M262B01 03 19A...
Страница 5: ...Wallbox ePark Instruction manual 5 8 Monitoring 58 9 Technical Data 60 Need help 63 Guarantee 63...
Страница 31: ...Wallbox ePark Instruction manual 31...
Страница 48: ...Wallbox ePark Instruction manual 48 A window will pop up in order to choose the file then click on upload...
Страница 59: ...Wallbox ePark Instruction manual 59 Monitoring...
Страница 62: ...Wallbox ePark Instruction manual 62...