Value
Description
Use OCPP time
synchronization
YES:
Synchronization of date and time -> Enabled.
NO:
Synchronization of date and time -> Disabled.
NOTE:
Date and Time is sent from backend on each heart-
beat response.
Compress OCPP
messages
YES:
Compress messages between Charge point and back-
end -> Enabled.
NO:
Compress messages between Charge point and backend
-> Disabled.
NOTE:
Before enabling this option consult to your backend
administrator if central system allows this function.
Energy for Start/Stop
transaction
PARTIAL:
Consumed value of energy by the vehicle sent be-
tween start and stop.
TOTAL:
actual count of the total accumulated energy meter
sent between start and stop.
Energy for MeterValues
PARTIAL:
Sends partial energy consumption while vehicle
is charging.
TOTAL:
sends the actual count of the total accumulated en-
ergy meter.
Stop charge if Start-
Transaction rejects the
user
YES:
Stop existing charge transaction after response from
backend (StartTransaction.conf) when user is blocked, ex-
pired or Invalid.
NO
:
Charge transaction does not stops even if backend re-
jects the user. (StartTransaction.conf)
NOTE:
Set this option according to your backend system.
Содержание Wallbox ePark
Страница 1: ...Wallbox ePark INSTRUCTION MANUAL M262B01 03 19A...
Страница 5: ...Wallbox ePark Instruction manual 5 8 Monitoring 58 9 Technical Data 60 Need help 63 Guarantee 63...
Страница 31: ...Wallbox ePark Instruction manual 31...
Страница 48: ...Wallbox ePark Instruction manual 48 A window will pop up in order to choose the file then click on upload...
Страница 59: ...Wallbox ePark Instruction manual 59 Monitoring...
Страница 62: ...Wallbox ePark Instruction manual 62...