SINGLE-PHASE CHARGE POINT
•
Connect to the
230V~.
THREE-PHASE CHARGE POINT
•
Connect to the
400V~
.
•
If the Power Supply is Single-Phase,
connect L1 and N.
Do not forget to connect the ground cable to the ground terminal
Terminal block maximum cross-section:
10mm
2
Make sure
all
screws are securely tightened at
4...5 Nm
S
Type of cable allowed by the terminal block: Copper
Cu
L
N
P
E
Protections
L1
L2
L3
N
P
E
Protections
External electric protections should be placed upstreams as shown below: