Wallbox eNext
Installation guide
25
Remote control function
I
Remote control function is a potential free contact which allows the charge transaction remote start
and stop.
BOR1 BOR4
ST
ART
CO
M
Dry
contact
This remote control function is disabled by default, by means of a jumper (as shown in the picture
below). You must remove the jumper to use this function.
BOR1 BOR4
JUMPER
DISABLED
ENABLED
NO JUMPER
BOR1 BOR4
Do not remove the jumper if remote control function is not
required, otherwise the charge transaction process cannot start.
When the jumper is removed, a device, outside of the Charge Point, should control the charge
transaction. This device should close the contact START to allow the charge transaction and if the EV
is connected to the Charge Point, it will start the charge transaction straight away.