The forks must be flat and supported firmly by the base. The cabinet must be raised by placing the 
forks underneath the profile that supports the unit.  

 

 

 

Unloading with a forklift 

3.3.- STORAGE  

The unit should be stored according to the following recommendations: 

Avoid placing it on uneven surfaces. 

Do not store it in outdoor areas, humid areas or areas exposed to splashing water. 

Avoid hot spots (maximum temperature: 45 ºC) 

Avoid saline and corrosive environments. 

Avoid  storing  the  unit  in  areas  where  a  lot  of  dust  is  generated  or  where  the  risk  of 
chemical or other types of contamination is present. 

Do not place any weight on top of the unit cabinets. 

 

4.- 

DISCLAIMER 

CIRCUTOR, SA reserves the right to make modifications to the device or the unit specifications 
set out in this instruction manual without prior notice. CIRCUTOR, SA advises the user to obtain 
the device's latest version of the specifications and applications at 

http://www.circutor.es

 

 

 

CIRCUTOR,  SA  recommends  the  use  of  the  original  cables  and  accessories 
supplied with the unit. 

 

5.- 

UNIT FEATURES 

 

5.1.- PERFORMANCE FEATURES 

- Step and contact analyzer based on current injection during one network cycle 
-  Provides  up  to  50  A  to  a  load  of  10  ohms  (test  earthing  plus  auxiliary  earthing).  At  5  A  the 
maximum loop resistance may be 110 ohms (test earthing plus auxiliary earthing).  
- Maximum voltage of 600 Vac. 
- Maximum power equivalent to 30 kV·A, with a weight of only 45 kg 
- Remote control via Bluetooth connection. The software is easily updated and customized. It can 
be controlled with any Microsoft Windows or Android device. We recommend the use of PDAs 
- Data storage, easy transfer to a PC 

Содержание Getest

Страница 1: ...INSTRUCTION MANUAL M98224701 03 13A...

Страница 2: ...has the skills and knowledge related to the construction and operation of the electrical equipment and installations and who has received safety training on the hazards involved WARNING Consult the i...

Страница 3: ...as a cabo exclusivamente por pessoal qualificado O C digo El ctrico Nacional define uma pessoa qualificada como uma pessoa que se encontre familiarizada com a constru o e opera o do equipamento assim...

Страница 4: ...______________________________________________ 9 5 1 PERFORMANCE FEATURES ________________________________________________________9 5 2 ELECTRICAL FEATURES ____________________________________________...

Страница 5: ...the unit throughout its working life In particular follow the installation standards indicated in the Low Voltage Directive and additional technical instructions The installation operation and mainte...

Страница 6: ...he instrument has two ergonomic handles and we recommend it be carried by two people The device also includes two electrodes These weigh 25 kg each This weight may be harmful if it is not lifted If th...

Страница 7: ...libration certificate Samsung Galaxy Young telephone with all its components charger box etc Cocodrile clamp Cable to connect the weights Measuring pick 2 switches Instruction Manual If any problem is...

Страница 8: ...The centre of gravity of some units may be found at a considerable height Therefore when handling with a forklift it is recommended that the unit be securely fastened and that no abrupt operations are...

Страница 9: ...ications to the device or the unit specifications set out in this instruction manual without prior notice CIRCUTOR SA advises the user to obtain the device s latest version of the specifications and a...

Страница 10: ...nt 15 Aac You need a low impedance power supply line to get maximum performance given that peaks of up to 130 A for 20 ms may appear when applying maximum power We recommend using cable with a cross s...

Страница 11: ...Compliance The device complies with EU directives LVD 2006 95 EC and EMC 89 336 EEC Due to the nature of the device an injection of several amps will cause some disturbances in the power supply lines...

Страница 12: ...nical service representative 6 1 INSTALLATION The Getest may be powered directly from the mains 230 Vac and 50 60 Hz or from a single phase generator set The required power of the generator set will d...

Страница 13: ...to perform the test as well as the current and voltage coils supplied with the unit 6 2 UNIT PARTS GETEST Wiring Max R 5A Max R 10A Max R 25A Max R 50A Power on indicator Safety switch 20 A D curve c...

Страница 14: ...GETEST Page 14 of 24 PDA Android PDA Windows Mobile...

Страница 15: ...the device to a line or generator capable of supplying the required power Required power 600 V x current to be injected 3 Flip the switch 6 The red LED will light up 4 Before connecting the telephone...

Страница 16: ...switch 5 to the Enabled position 9 Select the testing mode resistance step or contact If you select resistance you must indicate the test current In step and contact mode you must indicate the maximu...

Страница 17: ...nal b Current output contactor connection c Erratic voltage measurement d Test at 25 Vac e Injection of as a minimum the required current f Increased voltage if the desired current is not reached g In...

Страница 18: ...t must not exceed 10 Hardware earthing detail You must find or build a good auxiliary earthing as it will determine whether the unit can inject the test current Bearing in mind that the ohmic value of...

Страница 19: ...yellow green to the Getest s voltage terminals yellow green Run the other end to the weights one cable for each weight Arrange the weights one metre apart from each other simulating the passage of a p...

Страница 20: ...or substation Once the connections are made select step voltage mode in the PDA and enter the maximum fault current value provided by the supply company 7 2 CONTACT VOLTAGE To perform the contact test...

Страница 21: ...contact or resistance the auxiliary earth must be good enough to allow a correct measurement Bear in mind that a poor auxiliary earth adds a series resistance to the circuit which reduces the MPC dev...

Страница 22: ...oid version 1 Connect your telephone to the computer with a USB cable 2 Enable the phone s connection to the computer 2 Enter in My PC and select the Removable device icon 3 Open the desired file 9 WA...

Страница 23: ...ontinue There is a risk of electric shock The loop resistance is too high for the requested current MPC will apply the maximum power but will not be able to reach the required value Error impossible t...

Страница 24: ...to LV Regulations or that surpasses the limits indicated in the technical and environmental features of this manual In particular capacitor units are very sensitive to adverse environmental condition...

Отзывы: