8
Table 3 – _G3D_-400_ Pump Parts List
IDP
QTY DESCRIPTION
KIT
IDP
QTY
DESCRIPTION
KIT
1
1
Case
43
1
Bearing Retainer
2
1
Inlet
46
1
Inboard Cover
4
8
Hex Bolt (Foot Mount Only)
47
4
Brg. Retainer Hex Bolts
5
2
Pipe Plug (Foot Mount Only)
48
1
Bearing Spacer
(J-Seat Seal and DKH Only)
6
1
Pin Stop
XX
49
1
Bearing
X
7
1
Fastener Seal
X
50
1
Housing Spacer
9
2
Gasket (1 for C-Face)
X
51
2
Thrust Spacer
21
2
Idler
XX
52
2
Thrust Spring Lock Washer
22
1
Balance Piston Housing
(Foot Mount Only)
XX
53
2
Thrust Hex Bolt
23
2
Cups
XX
54
8
Hex Bolts
24
1
Rotor Housing
XX
63
1
Power Rotor
XX
25
1
Seal
X
64
1
Pipe Plug (Steel Only)
26
1
Tube
71
1
Tubing (C Face Only)
27
2
Tube O-ring
X
80
1
Seal Seat Adapter
(O-ring Seat Seal only)
28
2
Housing & Inboard Cover
O-ring
X
83
1
Seal Gasket
X
29
1
Thrust Plate
XX
86
1
Power Rotor Balance Piston
(C-Face Only)
XX
30
16
Washers (8 on C-Face)
79
2
90° Tube Fitting
(C-Face Only)
31
1
Key
88
1
Inlet O-ring
(Axial inlet pumps only)
X
38
1
Seal Spacer*
95
8
Nuts (C-Face only)
42
2
Retaining Ring
X
X = Minor Repair Kit Items.
XX = Major Repair Kit Items. (Items marked (X) are included in Major Repair Kit.)
* =
Not used in “DKH” pumps.
H. PUMP MAINTENANCE
WARNING
Failure to observe precautions while installing, inspecting and maintaining pump can cause injury to
personnel from accidental handling of liquids that may harm skin or clothing, or fire hazard risks from
flammable liquids, or injury from high pressure fluid jets.
DANGER
BEFORE
working on equipment, make sure all power to equipment is disconnected and locked-out.
H.1 GENERAL COMMENTS
NOTE:
Part number identifiers (IDP) contained within parenthesis, such as (9), refer to circled
numbers shown in pump parts list Tables 2 and 3 and on assembly drawings (figures
3 through 7).
De-energize driver before starting with any maintenance action.