18. Remove housing (2 or 24) and O-ring (6 or 28) from inlet end of case (1).  Discard O-ring 

(6 or 28). 

 

H.5 

PUMP ASSEMBLY  

 

NOTE:  

Prior to assembly of pump, clean and inspect all parts for nicks and burrs.  Replace 
all worn or damaged parts.  Imo Pump recommends replacement of all O-rings (6, 
28, 88), gaskets (8, 9, 44 or 83), mechanical seal (25) and ball bearing (15 or 49) 
when these parts are disturbed from their previously installed positions.  Coat all 
parts with light lubricating oil to assist in assembly. Inspect power rotor (11 or 63) 
shaft and remove any nicks or burrs which are present.

  

Polish power rotor shaft to 

remove any rust or oxidants that may be present under shaft sleeve.  

 

1.  Install O-ring (6 or 28) in groove in housing (2 or 24). Install O-rings (5 or 27) in grooves 

in tube (4 or 26) and install tube (4 or 26) in housing (2 or 24). 

 
2.  Install housing (2 or 24) O-ring end first, in pump case (1) from suction end until stop pin 

(46 or 6) slot is properly aligned.  Install stop pin (46 or 6) with fastener seal (45 or 7) in 
case (1).  

 
3.  If pump is C-face version (Figure 5 and 7) proceed below. If pump is foot mount, skip to 

step 4:  

 

a.  Clean and dry inboard cover (9 or 46) and balance piston bushing (33 or 86) mating 

surfaces with solvent.  Wipe Loctite “T747” Primer or equivalent onto the mating 
surfaces of bushing (33 or 86) and inboard cover (9 or 46).  Allow 1 to 5 minutes until 
primer is visibly dry.   Apply Locitite 609 or equivalent to bushing (33 or 86) and 
inboard cover (9 or 46) mating surfaces.  Assemble bushing (33 or 86) into inboard 
cover (9 or 46).  Allow 10 minutes to dry before proceeding with assembly.  

 

b.  Install O-ring (6 or 28) on inboard cover.  Install inboard cover (9 or 46) into discharge 

port side of case (1) using bolts (10 or 95) (and lock washers (92 or 30) if present).  
Ensure seal vent (57 or 5) is facing up and pin (4 or 26) in housing mates with hole in 
inboard cover (9 or 46).  Torque bolts (10 or 95) to value on assembly. Skip to step 7.  

 

4.  Install O-ring (6 or 28) on balance piston housing (47 or 22).  
 
5.  Install balance piston housing (47 or 22) in case (1) lining up hole in balance piston 

housing (47 or 22) with pin (4 or 26) in rotor housing (2 or 24).  

 
6.  Install gasket (8 or 9) on inboard cover (9 or 46).  
 
7.  Install inboard cover (9 or 46) into discharge port side of case (1) using bolts (10 or 4) 

(and lockwashers (92 or 30) if present).  Ensure seal vent (32 or 5) is facing up.  Torque 
bolts (10 or 4) to value on correct assembly drawing. 

 
8.  Assemble power rotor (11 or 63) and mechanical seal (25) as follows:  

 

Note:

  If no mechanical seal (DKH design in figure 4 and 6), assembly spacer (14 or 48) in 

inboard cover (9 or 46) and skip to step (f) below.  If pump has mechanical seal proceed with 
step (a) below. 
 

a.  Assemble spacer (38) onto shaft (11 or 63). 
 

Содержание G3D**-350 Series

Страница 1: ...The Imo General Installation Operation Maintenance and Troubleshooting Manual No SRM00046 as well as all other component manuals supplied with these type units should be read thoroughly prior to pump...

Страница 2: ...s can be done by removing seal vent set screw and pouring liquid into vent passageway before opening pump inlet Alternately seal chamber can be vented in situations where inlet pressure is above atmos...

Страница 3: ...ns where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of pump and or protection of pump itself are marked by the sign ATT...

Страница 4: ...y this manual In applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroughly reviewed to ensure proper fit of said equipment in...

Страница 5: ...tor T Carbide Seat X Special Material Or Construction 3rd Letter Designator S Steel casing T Carbide Seat X Special Material Or Construction 2nd Letter Designator C Circular Mounting Flange H Special...

Страница 6: ...er no circumstances are the following operating limits specified in table 1 to be exceeded without specific approval from Imo Pump Table 1 Normal Pump Operating and Structural Limits Condition Limit M...

Страница 7: ...C Face Only 10 16 Hex Bolts 36 1 Pipe Coupling C Face Only 11 1 Power Rotor XX 37 1 Tube Fitting C Face Only 13 2 Snap Rings X 38 1 Seal Spacer 14 1 Spacer Seal Seat Adapter X 42 1 Tubing C Face Only...

Страница 8: ...1 Power Rotor Balance Piston C Face Only XX 30 16 Washers 8 on C Face 79 2 90 Tube Fitting C Face Only 31 1 Key 88 1 Inlet O ring Axial inlet pumps only X 38 1 Seal Spacer 95 8 Nuts C Face only 42 2...

Страница 9: ...and key 16 or 31 2 Remove bearing retainer 17 or 43 from inboard cover 9 or 46 by removing bolts 18 or 47 and lockwashers 30 if present 3 Remove assembled power rotor 11 or 63 from inboard cover 9 or...

Страница 10: ...equire heating to loosen Loctite before bushing 33 or 86 can be removed Do not heat to more than 250 F 9 Remove inlet head 26 or 2 from case 1 by removing bolts 10 or 54 and lockwashers 92 or 30 if pr...

Страница 11: ...ivalent onto the mating surfaces of bushing 33 or 86 and inboard cover 9 or 46 Allow 1 to 5 minutes until primer is visibly dry Apply Locitite 609 or equivalent to bushing 33 or 86 and inboard cover 9...

Страница 12: ...t of clean system fluid or light oil on seal running face Install the rotating ring running face against the stationary seat face f Install inner snap ring 13 or 42 in groove of power rotor 11 or 63 g...

Страница 13: ...4 and lockwashers 92 or 30 if present Torque bolts to value on correct assembly drawing NOTE Inlet head 26 or 2 can be rotated and repositioned in 90 degree increments to suit suction piping To change...

Страница 14: ...ctory overhaul assistance contact your local Imo Sales Office or representative at Technical Customer Service Department in Monroe NC USA Most pumps have repair kits available Minor Repair Kits are us...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...OR International all rights reserved CIRCOR Pumps North America LLC 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 704 289 6511 Toll 1 877 853 7867 Email cc colfaxfluidhandling com Web c...

Отзывы: