background image

 

F.  OPERATION 

 

F.1  LIQUID LIMITATIONS 
 

Never operate with thin liquids such as solvents or water. Pump is designed for liquids having 
general characteristics of oil. 
 

F.2  OPERATING LIMITS 

 

 

CAUTION

 

 

ATTENTION

 

 

Operating conditions, such as speed, fluid viscosity, temperature, inlet pressure, discharge 
pressure, filtration, duty cycle, drive type, mounting, etc., are interrelated.  Due to these 
variable conditions, specific application limits may be different from operational limitations. 
Equipment must not be operated without verifying system operating requirements are 
within pump’s capabilities. 

 

Under no circumstances are the following operating limits (specified in table 1) to be exceeded 
without specific approval from Imo Pump. 
 

Table 1 – Normal Pump Operating and Structural Limits 

 

Condition 

Limit 

Maximum Speed 

 

2500 rpm 

Minimum Viscosity 

32 SSU 

Maximum Viscosity (figure 1) 

 

1

st

 Letter Designator B 

2500 SSU 

1

st

 Letter Designator H 

15000 SSU 

Minimum Liquid Temperature 

0°F 

Maximum Liquid Temperature (figure 1) 

 

1

st

 Letter Designator B 

180°F 

1

st

 Letter Designator H 

220°F 

Maximum Inlet Pressure 

50 psig 

Maximum Discharge Pressure (Continuous Duty) 

500 psig 

Filtration 

Refer to General Instruction Manual, CA-1 

Drive 

Direct or Belt 

Mounting 

Foot mounted in any attitude 

 

F3  Airborne Noise Levels (dBA) – 

 

F3a  – Measuring Conditions 

  Distance to Pump = 1 Meter 

  Operation = Cavitation Free 

  Tolerance ± 3 dB 

Содержание G3D**-350 Series

Страница 1: ...The Imo General Installation Operation Maintenance and Troubleshooting Manual No SRM00046 as well as all other component manuals supplied with these type units should be read thoroughly prior to pump...

Страница 2: ...s can be done by removing seal vent set screw and pouring liquid into vent passageway before opening pump inlet Alternately seal chamber can be vented in situations where inlet pressure is above atmos...

Страница 3: ...ns where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of pump and or protection of pump itself are marked by the sign ATT...

Страница 4: ...y this manual In applications where equipment furnished by Imo Pump is to become part of processing machinery these instructions should be thoroughly reviewed to ensure proper fit of said equipment in...

Страница 5: ...tor T Carbide Seat X Special Material Or Construction 3rd Letter Designator S Steel casing T Carbide Seat X Special Material Or Construction 2nd Letter Designator C Circular Mounting Flange H Special...

Страница 6: ...er no circumstances are the following operating limits specified in table 1 to be exceeded without specific approval from Imo Pump Table 1 Normal Pump Operating and Structural Limits Condition Limit M...

Страница 7: ...C Face Only 10 16 Hex Bolts 36 1 Pipe Coupling C Face Only 11 1 Power Rotor XX 37 1 Tube Fitting C Face Only 13 2 Snap Rings X 38 1 Seal Spacer 14 1 Spacer Seal Seat Adapter X 42 1 Tubing C Face Only...

Страница 8: ...1 Power Rotor Balance Piston C Face Only XX 30 16 Washers 8 on C Face 79 2 90 Tube Fitting C Face Only 31 1 Key 88 1 Inlet O ring Axial inlet pumps only X 38 1 Seal Spacer 95 8 Nuts C Face only 42 2...

Страница 9: ...and key 16 or 31 2 Remove bearing retainer 17 or 43 from inboard cover 9 or 46 by removing bolts 18 or 47 and lockwashers 30 if present 3 Remove assembled power rotor 11 or 63 from inboard cover 9 or...

Страница 10: ...equire heating to loosen Loctite before bushing 33 or 86 can be removed Do not heat to more than 250 F 9 Remove inlet head 26 or 2 from case 1 by removing bolts 10 or 54 and lockwashers 92 or 30 if pr...

Страница 11: ...ivalent onto the mating surfaces of bushing 33 or 86 and inboard cover 9 or 46 Allow 1 to 5 minutes until primer is visibly dry Apply Locitite 609 or equivalent to bushing 33 or 86 and inboard cover 9...

Страница 12: ...t of clean system fluid or light oil on seal running face Install the rotating ring running face against the stationary seat face f Install inner snap ring 13 or 42 in groove of power rotor 11 or 63 g...

Страница 13: ...4 and lockwashers 92 or 30 if present Torque bolts to value on correct assembly drawing NOTE Inlet head 26 or 2 can be rotated and repositioned in 90 degree increments to suit suction piping To change...

Страница 14: ...ctory overhaul assistance contact your local Imo Sales Office or representative at Technical Customer Service Department in Monroe NC USA Most pumps have repair kits available Minor Repair Kits are us...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...OR International all rights reserved CIRCOR Pumps North America LLC 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 704 289 6511 Toll 1 877 853 7867 Email cc colfaxfluidhandling com Web c...

Отзывы: