M039150CF
6
BURNER FEATURES
Burner model identification
Burners are identified by burner type and model. Burner model identification is described as follows.
Technical specifications
Type
HP72
Model
MG. AB.
S.
*.
A.
0.
40
(1)
(2)
(3)
(4)
(5)
(6) (7) (8)
(1)
BURNER TYPE
HP72
(2)
FUEL
M -
Natural gas
G -
Light oil
(3)
OPERATION
(
Available versions
()
AB -
Double stage
(4)
BLAST TUBE
S -
standard
(5)
DESTINATION COUNTRY
* - Destination countrysee data plate
(6)
BURNER VERSION
A - Standard
(7)
EQUIPMENT
0 =
2 gas valves
1 =
2 gas gas proving system
7 =
2 gas maximum gas pressure switch
8 =
2 gas gas proving maximum gas pressure switch
(8)
GAS CONNECTIONS
40 = Rp11/2 50 = Rp2 65 = DN65 80 = DN80
BURNER TYPE
HP60 MG....40
HP60 MG....50/65
HP65 MG.....50/65
Output
min. - max.kW
170 - 523
170 - 880
270-970
Fuel
Nat. gas - Light oil
Gas category
(see next paragraph)
Gas rate
min. - max. (Stm
3
/h)
18 - 55
18 - 93
29-103
Gas pressure
min. - max. mbar
(see Note 2)
Light oil rate
min. - max. kg/h
14 - 44
14 - 74
23-82
Light oil train inlet pressure
max. bar
2
Oil viscosity
2 - 7.4 cSt @ 40°C
Oil density
840 kg/m3
Power supply
400V 3N ~ 50Hz
Total power consumption
kW
2.15
2.15
2.55
Electric motor
kW
1.1
1.1
1.5
Pump motor
kW
0.55
0.55
0.55
Protection
IP40
Approx. weight
kg
65
72
107
Operation
Double-stage
Gas Train
40
50 - 65
50 - 65
Valves size/Gas connection
1”
1/2
/ Rp1
1/2
2” /Rp2 - 2”
1/2
/DN65
2” /Rp2 - 2”
1/2
/DN65
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermitent
BURNER TYPE
HP72 MG....0.50
HP72 MG.....0.65
HP72 MG....0.80
Output
min. - max.kW
330 - 1200
Fuel
Nat. gas - Light oil
Gas category
(see next paragraph)
Gas rate
min. - max. (Stm
3
/h)
35 - 127
Gas pressure.
min. - max. mbar
(see Note 2)
Light oil rate
min. - max. kg/h
28 - 101
Light oil train inlet pressure
max. bar
2
Oil viscosity
2 - 7.4 cSt @ 40°C
Oil density
840 kg/m3
Power supply
400V 3N ~ 50Hz
Total power consumption
kW
3.25
Electric motor
kW
2.2
Pump motor
kW
0.55
Protection
IP40
Approx. weight
kg
107
117
127
Operation
Double-stage
Gas Train
50
65
80
Valves size / Gas connection
2”/ Rp2
2”
1/2
/ DN65
3”
/ DN80
Operating temperature
°C
-10 ÷ +50
Storage Temperature
°C
-20 ÷ +60
Working service*
Intermittent
PART I: INSTALLATION MANUAL