M039150CF
19
1
Inlet G1/2
2
To the nozzle G1/2
3
Return G1/2
4
Pressure gauge port G1/4
5
Vacuum gauge port G1/4
6
Pressure governor
Keys
1
Pressure governor
2
Pressure/Vacuum gauge port to measure inlet pressure/vacuum
3
Pressure gauge port
5
Suction
7
To the nozzle
8
Return
Assembling the light oil flexible hoses
To connect the flexible light oil hoses to the pump, proceed as follows, according to the pump provided:
1
remove the closing nuts
A
and
R
on the inlet and return connections of the pump;
2
screw the rotating nut of the two flexible hoses on the pump
being careful to avoid exchanging the inlet and return lines
: see
the arrows marked on the pump that show the inlet and the return (see prevoius paragraph).
Suntec TA..
Oil viscosity
3 ÷ 75 cSt
Oil temperature
0 ÷ 150°C
Min. suction pressure
- 0.45 bar to avoid gasing
Max. suction pressure
5 bar
Max. return pressure
5 bar
Rotation speed
3600 rpm max.
Danfoss KSM..
Oil viscosity
2.5 ÷ 450 cSt
Oil temperature
-10 ÷ 160 °C
Max. suction pressure
4 bar
Min. suction pressure
-0.45 bar to avoid gasing
Max. return pressure
4 bar
Rotation speed
3450 rpm max
Suntec AJ6
Suntec E7
Danfoss RSF41
Suntec TA2
Danfoss KSM50
A
R
R
A
R
A
R
A
R
A