FuzzyScan
Pr
og
ram
mi
ng Man
ua
l
Configure Your FuzzyScan
77
Application Example
If your bar code label is a 16-digit Interleaved 2 of 5 which
includes the information of 6-digit date code, 6-digit serial
number and 4-digit unit price, you want the FuzzyScan do the
following for you without software modification:
Apply only Interleaved 2 of 5 to the condensed
DataWizard.
Check bar code is actually with 16-digit length.
Allow bar code output whose date code is leading with “9”.
Three outputs with “TAB” suffix.
The date code outpu
t should skip “9” and replaced it by
“A”.
The serial number output should be led with “SN”.
The unit price output should be skipped the first 2 digits.
Test Bar Code :
9 8 1 0 2 5
1 2 3 4 5 6
9 8 7 6
Actual Output :
A81025[TAB]SN123456[TAB]76[TAB]
Programming Procedure
[Data Verifier]
Scan “Program” to enter the programming mode.
Scan “Verifier Control” and set bar code symbology to
“
48
” (Interleaved 2 of 5).
Scan “Identified Data Length” and set the length to
“
16
”.
Scan “1st Identified Character” and set the identified
position to “
00
”, then set the identified character to “
39
”
(Hex Code of 9).
[Data Formatter]
Scan “Formatter Control” and set bar code symbology
to “
48
”.
Scan 1st Insertion” and set the identified position to
“
06
”, then inserted characters to “
09
” (Hex Code of
TAB), “
53
” (Hex Code of S), “
4E
” (Hex Code of N).
Scan “2nd Insertion” and set the identified position to
“
12
”, then inserted character to “
09
”. In the final, you
must scan “
FIN
” (Finish) code to terminate this
selection.
Scan “3rd Insertion” and set the identified position to
“
16
”, then inserted character to “
09
”. In the final, you
must scan “
FIN
” (Finish) code to terminate this
selection.