FuzzyScan
Pr
og
ram
mi
ng Man
ua
l
Configure Your FuzzyScan
62
[Code length]
Length: 4 byte
Specify what length of data output will be acceptable for this symbology. When you calculate the length, you must consider the whole data string which includes the
programmed Preamble, Postamble, Scanned Data Length, Prefix/Suffix Symbol ID or AIM ID. Scan the four digit data length from the
Option Code
.
Note: 40 characters is entered as 0040; 9999 is a universal number, indicating all lengths.
[Character match]
Length: 2-8 byte
You can refer to
HEX/ASCII Reference Table
to
find the Hex value that represents the character(s) you want to match. Use the
Option Code
to scan the
alphanumeric combination that represents the ASCII characters. You can match up to 4 characters which are counted from the start character of the whole
Data
String
.
Note: When setting the matched character(s), you must match the content of the whole Data String, including the programmed Preamble, Postamble, Scanned
Data Length, Prefix/Suffi Symbol ID OR AIM ID if you had defined.
FF
is the universal character, indicating all characters.
-
Batch Reading rule example
In this example, you are scanning Code 39, Code 128, and Code 93 bar codes, but you would like to output the data in following sequence:
Code 128 - Code 39 - Code 93
B-CODE39
A-CODE128
C-CODE93