Warning: Before cutting any holes, always check that you will not hit any electrical wiring or water pipes.

 

Failure to follow safety precautions may cause serious injury or death.

Make sure to mark the centreline before cutting 
any hole for installation of outlet and inlet pipes as 
shown in fig 3.

Before installing your new Cinderella toilet, please make sure to read each section of this installation manual carefully.

SELECT THE LOCATION

While planning to place the toilet, it is often useful to consider the free 
space around the toilet. Make sure to have enough space to both operate 
the toilet and sit properly. 

Ensure that the desired position of the toilet will not conflict with any other 
existing installation such as water pipes, ventilation pipes, electrical instal-
lations etc. The Cinderella Comfort is designed to operate on a 240V AC  
circuit with a minimum of 10 amps available. Make sure that you have 
enough electricity available and the intended receptacle is within range of 
where you plan to install the toilet (fig. 2).

Cinderella Comfort is approved for u

se in bathrooms/wet rooms (IP 34 classified), but water must not be splashed over the 

external parts of the toilet. For more information about rules for 

installations in wet rooms, please consult a plumber. The toilet 

must be placed on a firm and level base. Your Cinderella Comfort can be installed on a heated floor.

Planning and setting up the ventilation is an important part of the installation of your Cinderella toilet. There are several ways of 
installing the outlet pipe as well as inlet pipe. Proper installation will ensure optimal airflow and will not restrict the pipe flow.

Outlet Air Pipe:

It is recommended to install the outlet pipe vertically above the roof without any additional bends. Incorrect installation may 
cause poor incineration, odours and wear of the product. For detailed instructions on how to install the outlet pipe, please  
thoroughly read the section on how to install the outlet air pipe on page 8 - 9.

Inlet Air Pipe:

The Cinderella Comfort toilet is designed to make use of both air supplied into the room and air supplied directly through the 
inlet air connection in the back wall. For detailed instructions on how to install the air inlet vent and pipe, please thoroughly read 
the Inlet section on how to install the inlet air pipe on 10 - 11.

fig. 3

fig. 2

BEFORE INSTALLATION 

PLANNING  

YOUR VENTILATION

Содержание Comfort Australia

Страница 1: ...Model Cinderella Comfort Australia Language English INSTALLATION MANUAL...

Страница 2: ...ct the Location Planning Your Ventilation Page 7 Outlet Air Page 8 Installing the Outlet Air Pipe Installing the Outlet Air Pipe Through an Exterior Wall Installing Outlet Air Pipe Indoor Through the...

Страница 3: ...layed on the first text line The current language will be displayed on the second line 2 Push the Language select button repeatedly until the desired language is displayed 3 The new language will be s...

Страница 4: ...ugh the wall 4 Saw 5 Folding Ruler 6 Spirit level 7 Marking pencil 8 Knife Languages English French Cinderella Comfort Installation Manual Cinderella Comfort Model Comfort NA Languages English French...

Страница 5: ...5 598 29 12 540 528 586 Tittel Date Cinderella Comfort Side view 27 Scale 1 5 Units Metric mm Sheet size A3 598 10 350 390 362 180 15 Side view Front view CINDERELLA COMFORT DIMENSIONS IN MM...

Страница 6: ...fort Australia IMPORTANT NOTE Cinderella Comfort has a power consumption level of approximately 2000W while incinerating which may be sustained over periods exceeding an hour at a time Make sure that...

Страница 7: ...P 34 classified but water must not be splashed over the external parts of the toilet For more information about rules for installations in wet rooms please consult a plumber The toilet must be placed...

Страница 8: ...east 400 mm above the enclosure fig 7 IMPORTANT NOTE If the pipe perforates the roof surface ensure that it is in compliance with building regulations IMPORTANT NOTE Never use a fine mesh net in the v...

Страница 9: ...off a piece of the included long pipe to a minimum length of 80 mm Always make sure to preserve one of the bevelled pipe ends to be used when connecting the toilet to the pipe 1 Make a mark 35 mm from...

Страница 10: ...member to clean the vent at regular intervals Make sure that there is no conflict between the toilet s air supply and other installations such as a fireplace or extractor fan fig 12 Be aware that open...

Страница 11: ...tructions 1 Draw a mark in the Cinderella s centreline 150 mm from the floor fig 15 2 Pre drill a hole using a long drill bit through the interior and exterior wall in the centre of where you will dri...

Страница 12: ...ype of floor Use suitable screws VERIFYING INSTALLATION To ensure proper function of the system you can perform an easy performance test Performance test 1 Open the lid and seat Red light should be li...

Страница 13: ...with display 100115 2 Exhaust fan 100155 3 Hatch motor assembly 100858 4 Catalytic converter housing 100784 5 Heater element 101047 6 Battery 12V 2 6Ah 100083 7 Circuit board E5 V1 0 100063 8 Limit sw...

Страница 14: ...7 Place the new battery in position 8 Tighten the battery hose clip and reconnect the power leads fig 29 NOTE Make sure to connect the leads correctly I e Red to red black to black 9 Reconnect the ea...

Страница 15: ...to secure your warranty rights In the event of theft registered toilets will be in our manufacturer database After registration you will receive relevant information about our products and available s...

Страница 16: ...stributor Manufacturer cinderellaeco com Learn more about Cinderella Cinderella Eco Australia Pty Ltd Sydney New South Wales 2000 AUSTRALIA Phone 61 434 531 515 E mail sales australia cinderellaeco co...

Отзывы: