ENVIRONMENTAL REQUIREMENTS
•
Ambient temperature range: minus 20°C to 40°C
•
Operating altitude: Tested to 2500 m
POWER CONVERTERS: Power converters are not recommended for use with your Cinderella Comfort toilet. Cinderella Comfort
has a maximum power consumption level of 2000W, which may be sustained over period exceeding an hour at a time. Power
converters with a “peak consumption” level of 2000W may be unable to maintain this power output and become overloaded,
damaged or unsafe if used with your Cinderella Comfort Australia.
BATTERIES, GENERATORS and SOLAR PANELS are not sufficient as a power source for Cinderella Comfort Australia.
•
Power Supply
•
Current
•
Power Consumption
240/220VAC, 60 Hz
10 amp
2000W
All safety instructions in this manual are marked with this symbol. Please be sure to pay close
attention to all instructions given in this manual, especially when you see this symbol.
IMPORTANT NOTE:
Read this entire installation manual prior to installation. The homeowner should keep this installation
manual for future reference. Visit www.cinderellaeco.com for detailed step-by-step animations. It can be a good idea to look at
these animations prior to installing your new Cinderella Comfort Australia.
IMPORTANT NOTE:
Cinderella Comfort has a power consumption level of approximately 2000W while incinerating, which
may be sustained over periods exceeding an hour at a time. Make sure that your electrician takes this electrical load into consi-
deration upon installation.
IMPORTANT NOTE:
This appliance must be installed in accordance with National Electrical Codes, as well as all state,
municipal and local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated,
grounded circuit which is protected by a properly sized circuit breaker. The proper voltage, frequency and amperage are listed
in this manual, and on the product rating plate on the back of the toilet.
ELECTRICAL SPECIFICATIONS AND REQUIREMENTS
IMPORTANT NOTE:
Extension cords should not be used with this appliance.
When the Cinderella Comfort is installed, minimum clearance to combustible construction must be:
•
50 mm from sides
•
50 mm from rear
Warning: Before cutting any holes, always check that you will not hit any electrical wiring or water pipes
.
Failure to
follow safety precautions may cause serious injury or death
The Cinderella Comfort is designed to operate on a 240V AC circuit with a minimum of 10 amps available. Cinderella Comfort
Australia is delivered with a standard Australian (AU1-10P) plug.
AUSTRALIAN AU1-10P PLUG, 10A 250V
fig. 1
SPECIFICATIONS
AND REQUIREMENTS