9
INSTALLING THE OUTLET AIR PIPE THROUGH AN EXTERIOR WALL
1. In the centreline of the Cinderella’s chosen position, make a mark on the wall for the outlet air pipe 415 mm from the floor.
(fig. 6).
2. Drill a pilot hole with a long drill bit through the wall. Make sure you are holding the drill perpendicular to the floor (fig 7).
3. Expand the hole with a 111 mm diameter hole saw (fig. 8).
4. Make a mark 35 mm from the bevelled end of the pipe to indicate how far the pipe should be pressed into the toilet muff.
5. Install the supplied short air pipe through the wall (fig. 9).
6. Outdoors: Lubricate the muff of the T-piece and slide it onto the pipe protruding from the toilet (fig. 10).
7. Mount the vertical pipe and fix it to the wall with wall brackets.
8. Mount the ventilator cowl on top of the pipe.
9. Mount the T-piece plug.
fig. 9
fig. 10
INSTALLING OUTLET AIR PIPE INDOOR THROUGH THE CEILING
For the Cinderella toilet to be placed close to the wall, as shown in fig. 3, you need to cut off a piece of the included long pipe
to a minimum length of 80 mm. Always make sure to preserve one of the bevelled pipe ends, to be used when connecting the
toilet to the pipe.
1. Make a mark 35 mm from the end of the pipe, to indicate how far the pipe should be pressed into the toilet muff (fig. xx).
2. Lubricate the end with dishwashing detergent or a similar substance (fig. xx).
3. Press the pipe into the toilet muff, then attach the T-piece.
4. Place the toilet in the intended position.
5. Use a plumb line to mark the centre of the T-piece on the ceiling.
6. Drill a pilot hole with a long drill bit through both the ceiling and roof.
7. Expand the pilot hole with a 111 mm hole saw.
8. Ensure that the pipe is properly fed through the ceiling/roof. The pipe must be installed vertically above the roof and
extend at least 600 mm above the roof surface (fig. xx). If the outlet air pipe is to be enclosed (e.g. using metal siding),
make sure that the end of the pipe extends at least 400 mm above the enclosure (fig. 7).
IMPORTANT NOTE:
Make sure that the pipe is fed through the roof in compliance with building regulations. If you are
unsure, contact a qualified tradesman.
fig. 6
fig. 7
fig. 8