30
TANK BURNER:
Have your equipment inspected at regular intervals by a qualified service agency to assure continued
proper operation. The burner should be adjusted using dedicated combustion test equipment. Failure
to properly set the burner could result in inefficient operation, equipment damage and/or conditions
that could potentially cause severe personal injury, death or substantial property damage.
OWNER SERVICE AND MAINTENANCE
Daily:
Check the area around your burner/equipment to make
sure:
A. Nothing is blocking the burner inlet air openings.
B. Air ventilation openings are clean and unobstructed
and the exhaust is not crusted.
C. No combustible materials are stored near the
equipment.
Regular Service/Maintenance:
A. The following components/assemblies should be checked/adjusted/replaced on a regular basis.
See page 47 for more information and the tank burner parts exploded view .
B. Replace the diesel fuel supply line filter. The line filter cartridge must be replaced to avoid
contamination of the pump and nozzle.
C. Inspect the diesel supply system. All fittings should be leak-tight.
D. Verify the nozzle is the one originally specified by CIMLINE and always replace the nozzle with
one having the exact specifications from CIMLINE.
E. Clean and inspect the electrodes for damage, replacing any that are cracked or chipped.
F. Check electrode tip settings. Replace electrodes if tips are rounded.
G. Inspect the igniter spring contacts. Clean or replace if corroded.
H. Clean the cad cell (electric eye), if applicable.
I. Inspect all gaskets including the igniter base plate gasket. Replace any that are damaged or
missing.
J. Clean the blower wheel, air inlet, air guide, retention head and static plate of any dirt, asphalt or
other material.
K. Check motor current. The amp draw should not exceed the nameplate rating. Check all wiring
for loose connections or damaged insulation.
L. Check the pump pressure and cutoff function.
M. Check ignition system for proper operation.
N. Inspect the exhaust system for soot accumulation or other restriction.
Extended Down Time:
If the equipment will be stored for an extended period of time, insure that the fuel tank is full and add
a fuel stabilizer to the tank.
MA4 Maintenance - Tank Burner
Professional Service Required: Incorrect installation, adjustment,
and use of this burner could result in severe personal injury,
death, or substantial property damage.
WARNING
Beckett Corp. ADC 12V Tank Burner
Capacity:
Firing rate 0.75 - 2.50 GPH,
Input 105,000 - 350,000 Btu/h
Fuel:
(USA) No.1 or No.2 diesel fuel
Electrical:
Power Supply 13.5Vdc,
Operating load w/igniter on 15amps, w/
igniter off 8-10amps
Pump:
Outlet pressure 140psi