background image

6 Gallon Carpet Extractor

Models

EXTRACTOR

Operation & Maintenance Manual

Always obtain instruction form an authorized dealer. Unauthorized repair will void the warranty

2-100                         2-100-H
3-100                         3-100-H
2-200                         2-200-H
3-200                         3-200-H

US & Foreign Patents Pending

The design features herein are protected under the laws of the

United States Patent and Trademark Offi ce

Super Cooling Ducting System

Summary of Contents for Sniper 2-100

Page 1: ... dealer Unauthorized repair will void the warranty 2 100 2 100 H 3 100 3 100 H 2 200 2 200 H 3 200 3 200 H US Foreign Patents Pending US Foreign Patents Pending The design features herein are protected under the laws of the The design features herein are protected under the laws of the United States Patent and Trademark Office Super Cooling Ducting System ...

Page 2: ...al cord to a different outlet and resume operation PUMP SYSTEM Fill the solution tank and prime the pump 200 psi model only Turn the Auto Prime lever on Vertical Auto Prime lever is located on the backside of the machine near the left power cord Turn on a vacuum motor and cover vacuum inlet for 5 10 seconds Remove hand from inlet and turn the Auto Prime lever off Horizantal Turn solution pump on a...

Page 3: ...nt is inspected and tested before shipping from the manufacturer All parts are warranted to be new and free from defects in workmanship and material to the original retail purchaser as following 5 years on plastic body parts 2 years on electrical and motors 1 year on pump This warranty limits manufacturer s liability for defects in workmanship or materials to replacement of defective parts only Ma...

Page 4: ...ding circuit overloaded 4 Wiring connections loose 1 Check if machine and cord are plugged in 2 Check switches replace if necessary 3 Reset circuit 4 Unplug machine and check for loose wires 1 Vacuum motor hung up 2 Pump motor hung up 1 Replace Vacuum motor 2 Replace pump Pump System Pump is not running properly 1 No power to the pump 2 Jets on wand are clogged 3 In line water filter is clogged 4 ...

Page 5: ...haust Rebuild Kit for 500psi BPR Cooling Duct Cooling Duct Switch for Vacuum Switch for Vacuum Switch for Vacuum Lighted Switch for Heat Lighted Switch for Heat 10 0810 10 0810 10 0811 10 0811 10 1030 2 Stage 10 1030 2 Stage 10 1030 S 3 Stage 10 0812 10 0812 S 10 0869 10 0869 80 0012 80 0012 10 0805 10 0805 10 0804 10 0804 A 10 0868 10 0870 10 0845 10 0822 10 0803 10 0803 H 80 0061 T A001 T A001 8...

Page 6: ...EEN WHITE YELLOW RED BLUE M1 M2 PUMP Wiring Diagram Wiring Diagram Model 2 100 1 2 3 4 6 5 7 1 Solution Intake 2 Vacuum Hose 3 Vacuum Motor 1 4 Vacuum Motor 2 5 Vacuum Motor Manifold 6 100psi Solution Pump 7 Motor Cooling Ducting ...

Page 7: ...110VAC POWER SUPPLY BLACK WHITE GREEN WHITE YELLOW RED BLUE M1 M2 110VAC POWER SUPPLY BLACK WHITE Models 3 100 ...

Page 8: ...110VAC POWER SUPPLY M1 M2 HEATER 1 HEATER 2 HEATER 2 ORANGE BLUE BLACK WHITE YELLOW PURPLE RED WHITE WHITE 110VAC POWER SUPPLY BLACK Models 2 100 H 3 100 H ...

Page 9: ...110VAC POWER SUPPLY BLACK GREEN WHITE YELLOW RED BLUE M1 M2 PUMP Models 2 200 ...

Page 10: ...110VAC POWER SUPPLY BLACK WHITE GREEN WHITE YELLOW RED BLUE M1 M2 110VAC POWER SUPPLY BLACK WHITE Models 3 200 ...

Page 11: ...M1 M2 HEATER 1 HEATER 2 ORANGE BLUE BLACK WHITE YELLOW PURPLE RED WHITE WHITE 110VAC POWER SUPPLY 110VAC POWER SUPPLY BLACK Models 2 200 H 3 200 H ...

Page 12: ...110VAC POWER SUPPLY BLACK WHITE GREEN WHITE YELLOW RED BLUE M1 M2 PUMP 110VAC POWER SUPPLY BLACK WHITE GREEN Models 2 500 3 500 ...

Page 13: ...M1 M2 HEATER 1 HEATER 2 HEATER 2 ORANGE BLUE BLACK WHITE YELLOW PURPLE PURPLE RED 110VAC POWER SUPPLY BLACK Models 2 500 H 3 500 H ...

Reviews: