10. GROUND SPEED ENCODING WHEEL:
The ground speed encoding wheel has two red lights that are visible from
the tow vehicle.
A) The outboard “SYSTEM READY (SOLID)” light will
illuminate bright red and indicates when the computerized
control unit senses that the key fob remote is calling for
the application spray bar nozzles to be “ON” and applying
sealant.
B) The inboard “CORRECT SPEED (SOLID)” light will
illuminate bright red when the unit is traveling at an appro-
priate speed for the application rate programed. The light
will flash slowly if the unit is traveling too slow, and it will
flash quickly if the unit is traveling too fast for the sealant
material application rate.
9. KEY FOB REMOTE TRANSMITTER SPRAY CONTROL:
Use key fob remote transmitter to engage spray mode and control which nozzles are
active when ready to begin application of sealant material through the application spray
bar. NOTE: ONLY ONE REMOTE CAN BE USED AT A TIME. See page 20 for infor-
mation on pairing the key fob remote transmitter.
A) Power on the key fob remote transmitter using the “POWER ON / OFF” button at
the top of the remote.
B) When the key fob remote transmitter powers on, you should see the signal strength
light illuminate green indicating that the unit is on and communicating with the com-
puterized control panel.
C) Use the “START” (green) and “STOP” (red) buttons to begin and end application of
sealant material through the application spray bar.
D) The buttons numbered “1” through “5” control which spray nozzles are active on the application spray
bar while applying sealant material. Pressing a numbered button will activate and turn on a particular
nozzle and can be done “on-the-fly” while in application mode.
MPORTANT:
To turn off a particular nozzle while in application mode, you must press the
“STOP” button momentarily to reset the hydraulics and halt application, then press the “START” but-
ton again to continue application with the new nozzle settings.
E) The red light at the top of the key fob remote transmitter will indicate when the battery is low and re-
quires recharging.
MA4 Start Up Procedure
8. ACTIVATE THE ELECTRONIC CONTROL DISPLAY:
Press the “ACTIVATED/DEACTIVATED” button on
the computerized applicator control panel.
A) Verify the top left button is set to
“ACTIVATED” and the light next to the but-
ton is illuminated green.
B) Verify the control unit is set to “AUTO” and
the light next to that button is illuminated