background image

HOT AIR STATION CIF 852-A++ 

 

Ed 1102 

 

CIF 

 

Page 8 sur 24

 

 

4  Installation 

4.1  Work desk preparation 

 

You must have a working area with sufficient dimensions for the user to be easy. We strongly 
recommend dimensions of 1 metre X 1 metre. 
Working  area  must  be  a  tiled  straw  mattress,  a  metallic  or  synthetic  furniture  resistant  to 
800°C and situated in a well ventilated area. 
A  wash-hand  basin  situated  near  the  unit  is  recommended,  in  order  the  user  can  wash  his 
hands after handling of solder paste or solder wire. 
Power supply: 230 V mono + ground / 50 Hz on normalised plug 10A with differential circuit-
breaker 30mA. 
A special container is needed for rejects or dirty objects due to solder paste. 

4.2  Needed material 

 

As a complement to the CIF 852-A++ station, we recommend you use: 

 

* Our SMT products kit (item code F42 028) which includes: 

-

 

1 syringe 10 cc of no clean solder paste. 

-

 

1 flux cleaner, 400 ml spray. 

-

 

1 syringe of gel flux for repair. 

-

 

1 set of 50 polyethylene needles, diameter 0.4 mm. 

-

 

10 SMD boxes to store components. 

-

 

1 special SMT heating tweezers. 

-

 

1 roll of solder wire, 250 grs, diameter 0.5 mm. 

 
* Our ESD Mini-Kit (item code I43 202) which includes: 

-

 

1 ESD nat 300 x 400 mm. 

-

 

1 adjustable anallergic conductive bracelet. 

-

 

1 extensible cord. 

-

 

1 pressure linking cord + banana plug. 

 
* Our components handler « Vacuum Pen 1 » (item code article E53 018). 
* Our magnifier for inspection and control, 3 dioptries, 18 Watts « IMAGE 1 » (item code 
H41 023). 

4.3  Risks evaluation 

 
1-

 

Fire: the nozzle as well as the iron body reach high temperatures, please refer to 
chapters 3 & 4.1. 

Before storing the unit, ensure the iron gets cold

.

 

2-

 

Burns: see chapter 3. 

Once the unit stops, the nozzle as well as the metallic part of 

the iron are very hot ! Burns risk

3-   Toxicology: see chapters 4.1 and 10.1 upon the handling of solder paste or solder wire. 

See chapter 10.2 upon filtration aims. Have a look on the Safety Data Sheets of those 
products. 

Do not store any of those products along with foodstuffs.

 

Содержание 852-A++

Страница 1: ...V700044 INSTRUCTION NOTICE This document contains manufacturer s information which is protected by copyright All rights reserved This document cannot be copied reproduced or translated without written...

Страница 2: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 2 sur 24...

Страница 3: ...soci t C I F 92220 BAGNEUX France certifie que le produit r pond bien aux directives de la Communaut Economique Europ enne GB Manufacturer declaration C I F company 92220 BAGNEUX France herewith decl...

Страница 4: ...aration 8 4 2 Needed material 8 4 3 Risks evaluation 8 4 4 Assembly of the unit 9 5 START UP 11 6 PRECAUTION 16 6 1 Advice 16 7 STAFF PROTECTION 16 7 1 Solder paste and solder wire 16 7 2 Filtration a...

Страница 5: ...h digital display Environment friendly repairing system that integrates hot air gun and vacuum pen to pick up components Intelligent error reporting mechanism Detects and informs the personnel for pro...

Страница 6: ...pper Power Cord 1 2 Characteristics Power Input 220V Main Station Dimensions 188 w x 127 h x 244 d mm Weight 3 8 Kg HOT AIR Power Consumption 550W Temperature Range 100 C 480 C Heating Element Metal H...

Страница 7: ...the tool carrier is very hot This label is sticked on the unit ADVICE Sitting position no special installation needed Only use the unit in a well ventilated area The use without precaution can cause...

Страница 8: ...x cleaner 400 ml spray 1 syringe of gel flux for repair 1 set of 50 polyethylene needles diameter 0 4 mm 10 SMD boxes to store components 1 special SMT heating tweezers 1 roll of solder wire 250 grs d...

Страница 9: ...h this kind of waste Do not mix the waste 4 4 Assembly of the unit Unpack the unit and assemble the accessories Connect the iron to the unit screwing the connector Caution The switch must be on OFF or...

Страница 10: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 10 sur 24 Suction pen receptacle...

Страница 11: ...used to reconfigure temperature and airflow level settings Once pressed the system will temporarily switch to stand by mode then start the device using default temperature and airflow level values of...

Страница 12: ...t name The temperature heat and air level panel will both display OFF afterwards 2 Start the hot air gun by selecting Reworking from the Hot Air Gun switch F 3 The system will operate at 100 C tempera...

Страница 13: ...rn OFF the device by using the power switch 12 Unplug the unit from the power source RECOMMENDATION When adjusting the temperature it is strongly advised to increase the airflow level first in order t...

Страница 14: ...rature to bring down temperature to 90 C The panel will then display the following after reaching the safe temperature level and to indicate that the device is now in sleep mode NOTES Time is configur...

Страница 15: ...hile the device is adjusting the actual temperature The control panel will then display Axxx to indicate the actual temperature Note that actual temperature may vary for 5 of the defined value This is...

Страница 16: ...hands after each handling Put the rejects or dust remains in a container especially dedicated for that use 7 2 Filtration aims Gases and fumes produced during the different manufacturing phases are o...

Страница 17: ...e connected to a wide range of suction arms for many applications Ex Filter unit FILTRATEC F item code I51 025 Suction arms Conceived to be connected to the Filtratec units they are all ESD safe Diffe...

Страница 18: ...3 screws that secure the hot air gun handle The heating element is located in the middle part of the hot air gun 2 Slide off the plastic tube 3 Disconnect the ground wire sleeve 4 The Quartz glass and...

Страница 19: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 19 sur 24 NOTE The life expectancy of a heating element is 1 year under normal operating conditions 1 2 3 4...

Страница 20: ...few minutes SOLUTION The thermal sensor may be broken and needs to be replaced PROBLEM 3 ACTUAL AIR TEMPERATURE IS NOT INCREASING Description Actual temperature reading is not increasing or decreasing...

Страница 21: ...he device will also reset ail previously defined configurations PROBLEM 6 THE UNIT IS VIBRATING TOO MUCH Check if the 4 screws that hold the pump in place are properly and tightly connected Unplug the...

Страница 22: ...Reset button on the device Note that resetting the device will also reset aIl previously defined configurations OTHER PROBLEMS NOT MENTIONED Contact the vendor 9 Nomenclature scheme Reference Descrip...

Страница 23: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 23 sur 24...

Страница 24: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 24 sur 24 WWW CIF FR...

Отзывы:

Похожие инструкции для 852-A++