Suction Pen Assembly and Usage
Plug the end of the suction pen to its receptacle and attach a suction tip that matches the
particular IC to be used.
Suction strength can be increased by increasing the air pressure (button
C3
and
C4
). The
higher the air pressure the more powerful the suction strength.
To pick up ICs using the suction pen, increase air pressure to maximum, cover the hole at
the side of the suction pen while gently tapping the tip of the suction pen on top of the IC.
1. Turn ON the main power switch (H). The unit will display the product name.
T
he temperature (heat) and air level panel will both display “OFF” afterwards.
2.
Start the hot air
gun by selecting “Reworking” from the Hot Air Gun switch,
F
.
3.
The system will operate at 100°C temperature and 51 on the airflow level meter, by default. You
will also notice that the metal ball inside the airflow gauge is positioned somewhere in the middle.
The temperature (reading) may overshoot momentarily but will automatically adjust itself to reach
the desired (actual) value.
4.
Set desired air pressure by pressing C3 or C4 from the panel.
5.
Adjust hot air gun temperature by pressing buttons C1 or C2.
6.
You may start reworking as soon the actual temperature and desired airflox level have reached
values as shown from the display panel.
7.
After reworking, select “cool-down” from the Hot Air Gun switch.
Содержание 852-A++
Страница 2: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 2 sur 24...
Страница 10: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 10 sur 24 Suction pen receptacle...
Страница 23: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 23 sur 24...
Страница 24: ...HOT AIR STATION CIF 852 A Ed 1102 CIF Page 24 sur 24 WWW CIF FR...