EN - 26
LED
PROG
button
Batteries
Pairing the outdoor sensor
Warning: to pair the sensor in the same way as the terminal, a minimum of Level 2 access is required (see paragraph 5.2).
It is strongly recommended that this sequence is performed before positioning the outdoor sensor on the front of the
frame.
The pairing procedure for the outdoor sensor is always performed using the control terminal.
Sensor stimulation procedure
1- Place the 2 batteries in the outdoor sensor, observing the
polarity.
After fitting the batteries, check the status of the LED:
- if the LED is lit green for a few seconds, the battery level is
correct.
- if the LED flashes orange or does not come on, the battery
level is too low. Replace the batteries before starting the pairing
procedure.
2- Press and hold the PROG button again for 3 seconds until the
LED lights up steady green
The information on the display
.
°C
indicates that there is no
communication between the terminal and the outdoor sensor.
Turn the knob
to "Unit parameter"
then confirm the selection using the
CLIC
button
MAIN MENU
u
niT
configuraTion
Select
"Pairing" using the
CLIC
button then confirm
UNIT CONFIGURATION
B
ack
PAIRING
Select
"Heat pump pairing" using the
CLIC
button then confirm
PAIRING
B
ack
SYSTem
pairing
m
ainTenance
Heat pump PAIRING
Select
"Outdoor sensor" using the
CLIC
button then confirm
HEAT PUMP PAIRING
H
eaT
pump
B
ack
OUTDOOR SENSOR
Select
"Add" using the button then confirm
CLIC
OUTDOOR SENSOR PAIRING
B
ack
ADD
During the pairing phase, if the LED changes from green
to red/orange, this means that the battery voltage level is
insufficient. Replace the batteries and press the PROG button
again until the LED lights up steady green again.