0
1
2
3
4
5
6
7
8
9
10
0
1
2
3
4
5
6.7
8
9~15
Multi-Function Terminal
F093 X1 Multi-Function Input Terminal Function Choice
Setting Range: 0~9 Factory Setting: 0
F094 X2 Multi-Function Input Terminal Function Choice
Setting Range: 0~9 Factory Setting: 1
F095 X3 Multi-Function Input Terminal Function Choice
Setting Range: 0~9 Factory Setting: 2
F096 X4 Multi-Function Input Terminal Function Choice
Setting Range: 0~9 Factory Setting: 5
F093 ~ F096 multi-function input terminal function choice content in below table:
Parameter Value
Function Content
Multi-function speed 1
Multi-function speed 2
Multi-function speed 3
Outer pushbutton up
Outer pushbutton down
Outer crawl function
Outer NC stop pushbutton
Outer free stop
Counter pulse input
Counter zero clearing
Reversed inching
F097 Relay Output Terminal Function Choice Setting Range: 0~15
Factory Setting: 3
F097 Y1 Multi-Function Output Terminal Function Choice
Setting Range: 0~15 Factory Setting: 0
F097 Y2 Multi-Function Output Terminal Function Choice
Setting Range: 0~15 Factory Setting: 0
F097~F099 multi-function output terminal function choice content is as below table:
Parameter Value
Function Content
In operation
Frequency reached to Top
Set frequency arrived
Fault output
Under voltage
Count arrives
Ineffective
In stop
Conservation
Protection Function
F100 Deceleration Over-voltage Stall-prevention Function Setting
Setting Range: 110~150% Factory Setting: 130%
Function Instruction: In deceleration operation of Inverter, when output voltage exceeded
this set value, Inverter would stop deceleration and continue deceleration after
current restored to be below the set value.
F101 Constant-Velocity Over-voltage Stall-prevention Function Setting
Setting Range: 110~150% Factory Setting: 130%
Function Instruction: In operation of Inverter, due to many reasons, output voltage
may exceed this set value, Inverter would reduce output frequency and continue
recovery to operation frequency after voltage restored to be normal.
F102 Acceleration Over-current Stall-prevention Function Setting
Setting Range: 80~180% Factory Setting: 130%
Function Instruction: In acceleration of Inverter, when output current exceeded this
set value, Inverter would stop acceleration and continue acceleration after current
restored to be below the set value.
F103 Constant-Velocity Over-current Stall-prevention Function Setting
Setting Range: 80~180% Factory Setting: 130%
Funct ion In struc tion: In operation of Inverter, due to mechanical character, mechanical
impact or overload, Inverter will overload and occur jump fault, when Inverter
rotation current exceed set value, Inverter will reduce output frequency and
continue recovery to operation frequency after voltage restored to be normal.
F104 Reverse Rotation Forbidden Function Setting Range: 0~1 Factory Setting: 1
F014=0: Allow reverse rotation.
F014=1: Forbid reverse rotation
Function Instruction: Such function is used to choose whether motor has forbidden the
reverse rotation.
F105 Parameter Lock Setting Range: 0~1 Factory Setting: 0
F015=0: Ineffective.
F015=1: Effective.
Function Instruction: When F015=1, all parameter modification will be ineffective
(except operation frequency F000), data will not be conserved.
F106 Absorption of Vibration Function Setting Range: 0~1 Factory Setting: 1
F016=0: Ineffective.
F016=1: Effective.
Function Instruction: Such function is used to choose motor vibration function.
Note: When input voltage is 200V, please do not choose such function to be effective.
F107 Frequency Memory Function Setting Range: 0~1 Factory Setting: 1
F017=0: Memorize start frequency.
F017=1: Memorize current frequency.
Function Instruction: Such function is used to set whether the randomly adjusted
operation frequency after the power-off will be memorized and save.
Fault Function
F108 Fault Record 1 Display Content: 0~15
F109 Fault Record 2 Display Content: 0~15
F110 Fault Record 3 Display Content: 0~15
Article6 Function parameter illustration
Article6 Function parameter illustration