F025 Sector 2 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:5.0HZ
F026 Sector 2 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F027 Sector 2 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 2 speed, when the Inverter is operated in multi-
speed or by program.
F028 Sector3 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:10.0HZ
F031 Sector 4 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:20.0HZ
F034 Sector 5 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:30.0HZ
F037 Sector 6 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:40.0HZ
F040 Sector 7 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:50.0HZ
F043 Sector 8 Speed Frequency Setting Range: Bottom Frequency ~Top
Frequency Factory Setting:50.0HZ
F029 Sector 3 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F032 Sector 4 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F035 Sector 5 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F038 Sector 6 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F041 Sector 7 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F044 Sector 8 Speed Acceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F030 Sector 3 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F033 Sector 4 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F036 Sector 5 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F039 Sector 6 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F042 Sector 7 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
F045 Sector 8 Speed Deceleration Time Setting Range:0.0~999.9S Factory
Setting:10.0S
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 3 speed, when the Inverter is operated in multi-
speed or by program.
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 4 speed, when the Inverter is operated in multi-
speed or by program.
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 5 speed, when the Inverter is operated in multi-
speed or by program.
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 6 speed, when the Inverter is operated in multi-
speed or by program.
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 7 speed, when the Inverter is operated in multi-
speed or by program.
Function Instruction: These functions are used to set the frequency, acceleration time,
deceleration time of the sector 8 speed, when the Inverter is operated in multi-
speed or by program.
Program Operation
In program operation, operation frequency, acceleration time and deceleration time
is set by multi-sector speed function F025~F045, F000 participate operation as the
frequency of program operation 1 and acceleration/deceleration time of F018, F019.
F046 Program Operation Mode Setting Range: 0~3 Factory Setting: 0
F046=0: invalid
F046=1: monocycle operation and stop
F046=2: continuous cycle operation
F046=3: monocycle operation and operation in last frequency.
Note 1: When choosing monocycle operation and stop (F046=1), finish one cycle and
stop operation according to the set sectors.
Note 2 : When choosing continuous cycle operation (F046=2), continuously cycle operation.
Note 3: When choosing monocycle operation and operation in last frequency (F046=3),
finish one cycle and operate in last frequency according to the set sectors.
F047 Program Operation Time coefficient Setting Range: 0~100 Factory Setting: 1
Function Instruction: Such function is used to set operation time coefficient of the
program operation, multiplying operation set time to be actual operation time.
For example: Set this coefficient to be 10, set program operation 1 time t o be 1.0S,
then the actual operation time is 10.0S.
F048 Program Operation 1 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F050 Program Operation 2 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F052 Program Operation 3 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F054 Program Operation 4 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F056 Program Operation 5 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F058 Program Operation 6 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F060 Program Operation 7 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
F062 Program Operation 8 Time Setting Range: 0.0~999.9 Factory Setting: 0.0
Function Instruction: Above functions is used to set the operation time value of the program
operation sector 1~8, when set to be 0.0, it doest not participate the program operation.
F048 Program Operation 1 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F050 Program Operation 2 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F052 Program Operation 3 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F054 Program Operation 4 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F056 Program Operation 5 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F058 Program Operation 6 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F060 Program Operation 7 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
F062 Program Operation 8 Direction Setting Range: 0.0~999.9 Factory Setting: 0.0
Function Instruction: Above functions is used to set the direction of positive and reverse
rotation of the program operation sector 1~8, 0: positive rotation and 1: reverse rotation.
Article6 Function parameter illustration