PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual.docx
48
9.5 EU declaration of conformity for allPIXA SIWR CameraLink
cameras
Страница 1: ...allPIXA SWIR GigE Camera Manual CD40199 R01 2022 06 02 PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual docx...
Страница 2: ...ra 14 3 4 Purpose applications 14 3 5 Staff requirements 15 3 6 Organizational measurements 15 3 7 Safety instructions for maintenance cleaning 15 3 8 Maintenance and cleaning of the allPIXA SWIR came...
Страница 3: ...mera and illumination 35 7 4 Creating flat field correction tables 37 8 Troubleshooting and support 40 8 1 Returning material obtain an RMA number 40 8 2 Temperature warnings and errors 40 8 3 Before...
Страница 4: ...y assurance monitoring Customers from all over the world of a wide range of industrial sectors have placed their trust in the experience of Chromasens in the field of industrial image processing 1 1 1...
Страница 5: ...ed pattern noise FPN DVAL Data valid Pixel by pixel enabled for Camera Link FFC Flat field correction Can be used to correct the fixed pattern noise of the image sensor the vignetting of the lens and...
Страница 6: ...t of data to be transferred or to increase the achievable frame rate RS422 RS 422 TIA EIA 422 Technical standard for Differential Interface Circuits See e g RS 422 Wikipedia SDK Software Development K...
Страница 7: ...g plate is located on the rear of the allPIXA SWIR camera It shows the camera resolution and the serial number Additionally ordered and supplied accessories Cables extension rings lenses and other acc...
Страница 8: ...illumination 3 has integrated temperature sensors which can be read out with the XLC4 controller By use of the XLC4 controller the illumination unit can be monitored and kept stable 4 Network cable an...
Страница 9: ...highlights The allPIXA SWIR camera is especially suitable for inspection systems requiring a very high speed and a consistently high image quality Short wave infrared line scan camera High speed InGaA...
Страница 10: ...where the products shall be exported to or shall be imported into 2 4 Technical specification Sensor InGaAs short wave infrared line sensor Spectral sensitivity 950 nm to 1700 nm Resolution 1024 px or...
Страница 11: ...e which is available on the allPIXA SWIR download page https chromasens de allpixa swir downloads and to the GenICam Standard Features Naming Convention SFNC which is available free of charge on the G...
Страница 12: ...nsor lines of different camera models vary in length depending on maximum resolution and pixel size Figure 2 Camera sensor line location NOTE The logo Chromasens on the side of the camera indicates th...
Страница 13: ...n DHCP On Current IP Configuration Persistent IP Off To use DHCP or LLA autoconfiguration you have to disable Persistent IP as this has the highest priority 3 Safety 3 1 Depiction of safety instructio...
Страница 14: ...re carrying out any work on the unit Electric voltage hazard The allPIXA SWIR camera runs with electric power Before any work is carried out on the allPIXA SWIR camera be aware to disconnect the mains...
Страница 15: ...operation commissioning maintenance and repair must be clearly defined and specified by the owner of the device in which the allPIXA SWIR camera is installed 3 6 Organizational measurements The instru...
Страница 16: ...e cleaning the device make sure that the device is disconnected from the power supply All surfaces requiring cleaning can be wiped with a soft lint free cloth which can be moistened with Isopropanol N...
Страница 17: ...e with the host application The allPIXA SWIR camera can be used and configured with any GigE Vision 2 0 compliant Software or SDK We recommend using the Chromasens GenICam Control Tool GCT and the Chr...
Страница 18: ...2 1024 Pixel size m 25 x 25 12 5 x 12 5 Pixel pitch m 25 12 5 Figure 4 Camera sensor block diagram 4 2 2 Spectral sensitivity The figure below represents the spectral response of the camera sensor spe...
Страница 19: ...for power supply A red power LED which indicates whether the allPIXA SWIR camera is connected to the power supply An orange status LED which blinks as soon as the camera firmware has booted successful...
Страница 20: ...ailable I O cables see section 9 3 4 You can connect up to three digital input signals and two digital output signals to the digital I O connector of the camera Figure 7 I O connector on camera male f...
Страница 21: ...nnection is required additionally between the source for example encoder and the drain camera GND I O ground reference Requirements when using single ended Low Voltage TTL input signals Do not connect...
Страница 22: ...ital Output 2 Figure 9 Output schematic Output lines can be configured in the Digital IO Control feature group Please note that this feature Group is only visible in user level Expert or higher not in...
Страница 23: ...ce On the backside of the camera you find the following interfaces Two Camera Link MDR connectors for image data transfer and communication between the allPIXA SWIR camera and the image processing com...
Страница 24: ...conveyor belt moving with variable speed Adapt camera line rate to transport speed of the object by means of an incremental encoder signal to get undistorted images Refer to section 5 6 and 5 1 3 on...
Страница 25: ...this case the rotating direction of the encoder cannot be detected 8 Encoder Divider Float specifies the number of encoder steps needed to generate an encoder output pulse to be used as line trigger...
Страница 26: ...fer to section 5 6 and 5 1 3 on how to connect the external line trigger to the digital I O connector of the camera Feature settings in feature group Acquisition Control Trigger Selector Line Start Tr...
Страница 27: ...xed Refer to section 5 6 and 5 1 3 on how to connect the light barrier to the digital I O connector of the camera Feature settings in feature group Acquisition Control Trigger Selector Frame Start Tri...
Страница 28: ...d flat surface A thermal connection to heat conductive parts has a positive effect on operation of the allPIXA SWIR camera To dissipate the heat more effectively to the surrounding area we also recomm...
Страница 29: ...onnected and screwed check the cable configuration The weight of the cables must not be applied to the connectors No other mechanical load should be applied to the connectors Comply with the minimum p...
Страница 30: ...o the power supply 5 6 2 Connecting external I O devices to the allPIXA SWIR GigE camera You can connect up to three digital input signals and two digital output signals to the digital I O connector o...
Страница 31: ...SE T network connection Use a Cat 5e Cat 6 or better S STP Gigabit Ethernet cable and a suitable Gigabit Ethernet network adapter in the computer Figure 15 Connecting the allPIXA SWIR camera to the co...
Страница 32: ...cannot be detected by GCT or if the camera shows up but cannot be opened it may be necessary to adjust the configuration of the network adapter of your computer or the network settings of the camera...
Страница 33: ...12 24 VDC 10 typically 6 W see section 5 6 3 Install and configure the network adapter on your PC See GCT manual 4 Adjust the focusing point of your illumination unit and position it correctly Refer t...
Страница 34: ...ggers and set the camera to free run mode If you have already changed settings on the camera and do not want to lose them save them in a custom User Set before you load the Default user set To load th...
Страница 35: ...lumination visible while adjusting the illumination Special adjustment tools or rulers customized to your scanning system can be very helpful when setting up and aligning camera and illumination To ad...
Страница 36: ...p When the Resulting Line Rate drops below your speed requirements defined by camera resolution and transport speed increase illumination intensity LED current or Sensor Gain in the Gain Selector of t...
Страница 37: ...erefore make sure to cover front lens and or turn the illumination off before executing the command In a similar way the PRNU calibration wizard will capture and use an image of the moving white refer...
Страница 38: ...er Set 1 and download this user setting also to a file on your computer and restore it for later re calibrations To save the current camera settings to User Set 1 select User Set 1 in the User Set Sel...
Страница 39: ...RNU Dataset to be activated in User Set 1 save the current settings to User Set 1 in the User Set Selector of the User Set Control feature group by executing the User Set Save command Please note that...
Страница 40: ...y Phone 49 0 7531 876 0 Fax 49 0 7531 876 303 E Mail support chromasens de Internet https www chromasens de For return of material you should use the original packaging material to avoid any damages t...
Страница 41: ...all relevant information beforehand This ensures fast and efficient problem solving with the Chromasens technical support We recommend using the form in appendix 9 1 as a guideline to collect the mos...
Страница 42: ...he problem occur once always regularly rarely please describe Did the application ever run ok yes no If known please describe the reason for the problem or any abnormal behavior Image and Parameter Fi...
Страница 43: ..._CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual docx 43 9 2 Mechanical specification 9 2 1 Mechanical dimensions of the allPIXA SWIR GigE camera Figure 16 Mechanical dimensions of the allPIXA SWIR came...
Страница 44: ...ion CP000430 allPIXA Power Supply 1 5m banana plugs CP000504 allPIXA Power Supply 5m banana plugs T18419 TAG 7 Power Supply cable 5m ferrules The power supply connector is also available separately Ma...
Страница 45: ...needed Figure 18 F Mount adapter dimensions Description Description 1 Fastening screw 3 Fastening ring 2 Adapter 4 Release button 9 3 4 I O Cables The I O cable is available in two variants Order Code...
Страница 46: ...PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual docx 46 Figure 19 T18445 TAG 7 12 PF HIROSE PLUG STRAIGHT OPEN LEADS CABLE Figure 20 T18446 TAG 7 12 PF HIROSE PLUG RIGHT ANGLE OPEN LEADS Cable...
Страница 47: ...PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual docx 47 9 4 EU declaration of conformity for allPIXA SIWR GigE cameras...
Страница 48: ...PMA_CHR_CD40199_R01_allPIXA_SWIR_GigE_User_Manual docx 48 9 5 EU declaration of conformity for allPIXA SIWR CameraLink cameras...
Страница 49: ...allPIXA_SWIR_GigE_User_Manual docx 49 Chromasens GmbH Max Stromeyer Stra e 116 Phone 49 7531 876 0 https chromasens de 78467 Konstanz Fax 49 7531 876 303 info chromasens de Germany June 2022 Copyright...