Charge/Discharge Controller 69200-1 User’s Manual
3-18
Command
Parameter
Description
SOURce:TIME:CUTOFF Cutoff Time
Unsigned integer. Set the cutoff time parameters.
Unit (Sec). Range 0 to 65535
Syntax: SOURce:TIME:CUTOFF
Parameter: 12
Return Value: None
Command
Parameter
Description
SOURce:TIME:CUTOFF? None
Unsigned integer. Query cutoff time setting value.
Syntax: SOURce:TIME:CUTOFF?
Parameter: None
Return Value: 12
Command
Parameter
Description
SOURce:VOLT
Voltage Setting
Value
Float. Set the voltage parameters. Unit (V). There
are three decimal points. Range based on
machine specifications.
Syntax: SOURce:VOLT
Parameter: 10.003
Return Value: None
Command
Parameter
Description
SOURce:VOLT? None
Float. Query voltage setting value.
Syntax: SOURce:VOLT?
Parameter: None
Return Value: 10.003
Command
Parameter
Description
SOURce:CURR
Current Setting
Value
Float. Set the current parameters. Unit (A). There
are three decimal points. Range based on
machine specifications.
Syntax: SOURce:CURR
Parameter: 5.001
Return Value: None
Command
Parameter
Description
SOURce:CURR?
None
Float. Query current setting value.
Syntax: SOURce:CURR?
Parameter: None
Return Value: 5.001
Command
Parameter
Description
SOURce:POW
Power Setting
Value
Float. Set the power parameters. Unit (W). There
are three decimal points. Range based on
machine specifications.
Syntax: SOURce:POW
Parameter: 50.025
Return Value: None
Содержание 69200-1
Страница 1: ......
Страница 2: ......
Страница 3: ...Charge Discharge Controller 69200 1 User s Manual Version 1 3 April 2017...
Страница 8: ...vi...
Страница 12: ......
Страница 14: ......
Страница 20: ......
Страница 70: ......
Страница 78: ......
Страница 80: ...Charge Discharge Controller 69200 1 User s Manual 5 2 please notify Chroma for calibration...
Страница 82: ......
Страница 84: ......