Charge/Discharge Controller 69200-1 User’s Manual
3-24
Command
Parameter
Description
MEAS:POW?
None
Query measurement power.
Syntax: MEAS:POW?
Parameter: None
Return Value:
Parameter
Data Type
Description
Meter Power
float
Measurement power. Unit (W). There are three
decimal points.
Command
Parameter
Description
MEAS:AH?
None
Query measurement AH.
Syntax: MEAS:AH?
Parameter: None
Return Value:
Parameter
Data Type
Description
Meter AH
float
Measurement AH.
Command
Parameter
Description
MEAS:KWH?
None
Query measurement KWH.
Syntax: MEAS:KWH?
Parameter: None
Return Value:
Parameter
Data Type
Description
Meter KWH
float
Measurement KWH.
Command
Parameter
Description
MEAS:DCIR?
None
Query measurement DCIR.
Syntax: MEAS:DCIR?
Parameter: None
Return Value:
Parameter
Data Type
Description
Meter DCIR
float
Measurement DCIR. Unit (Ω).
Command
Parameter
Description
BATT:SPEC:ALL?
Voltage high limit Float. The maximum voltage value. Unit (V)
Voltage low limit Float. The minimum voltage value. Unit (V).
Current
Float. The maximum current value. Unit (A).
Power
Float. The maximum power value. Unit (W).
I slew rate
Float. The maximum current slew rate value. Unit
(A/ms).
ESR high limit
Float. The maximum ESR value.
Unit (Ω).
ESR low limit
Float. The minimum ESR value.
Unit (Ω).
BVH high limit
Float. The maximum BVH voltage value. Unit (V)
BVH low limit
Float. The minimum BVH voltage value. Unit (V).
BVL high limit
Float. The maximum BVL voltage value. Unit (V)
BVL low limit
Float. The minimum BVL voltage value. Unit (V).
Содержание 69200-1
Страница 1: ......
Страница 2: ......
Страница 3: ...Charge Discharge Controller 69200 1 User s Manual Version 1 3 April 2017...
Страница 8: ...vi...
Страница 12: ......
Страница 14: ......
Страница 20: ......
Страница 70: ......
Страница 78: ......
Страница 80: ...Charge Discharge Controller 69200 1 User s Manual 5 2 please notify Chroma for calibration...
Страница 82: ......
Страница 84: ......