Installation
3-15
Parameter: None
Return Value: 1
Command
Parameter
Description
CHANnel:ID?
None
Query the tester to identify.
Syntax: CHANnel:ID?
Parameter: None
Return Value:
It returns 69225-60,000000000000,01.00,1.00 when connected to Tester.
It returns NONE when no Tester is connected.
Command
Parameter
Description
OUTPut:STATe
Output
Set output status. (ON/OFF/PAUSE/CONTINUE)
Syntax: OUTPut:STATe
Parameter: OFF
Return Value: None
Command
Parameter
Description
OUTPut:STATe?
None
Query output status. (OFF LINE/OFF/ON/
PAUSE/PROGRAM)
Syntax: OUTPut:STATe?
Parameter: None
Return Value: OFF
Command
Parameter
Description
OUTPut:MODe
Output Mode
Set output mode (0: Manual Test/1: Battery
Simulator).
Syntax: OUTPut:MODe
Parameter: 0
Return Value: None
Command
Parameter
Description
OUTPut:MODe?
None
Query output mode.
Syntax: OUTPut:MODe?
Parameter: None
Return Value: 0
Command
Parameter
Description
SPECification:ALL?
Voltage high limit
value
Float. The maximum voltage value. Unit (V)
Voltage low limit
value
Float. The minimum voltage value. Unit (V).
Current limit value Float. The maximum current value. Unit (A).
Power limit value Float. The maximum power value. Unit (W).
I slew rate limit
value
Float. The maximum current slew rate value. Unit
(A/ms).
ESR high limit
value
Float. The maximum ESR value.
Unit (Ω).
ESR low limit value Float. The minimum ESR value.
Unit (Ω).
CR high limit value Float. The maximum resistance value in CR
mode.
Unit (Ω).
Содержание 69200-1
Страница 1: ......
Страница 2: ......
Страница 3: ...Charge Discharge Controller 69200 1 User s Manual Version 1 3 April 2017...
Страница 8: ...vi...
Страница 12: ......
Страница 14: ......
Страница 20: ......
Страница 70: ......
Страница 78: ......
Страница 80: ...Charge Discharge Controller 69200 1 User s Manual 5 2 please notify Chroma for calibration...
Страница 82: ......
Страница 84: ......