Local Operation
3-77
EEPROM using the
SAVE
key. Later you can recall the settings from the specified file via
RECALL
key. There are ten files (file = 0 ~ 9) under each mode can be saved.
AC Load will automatically load file 0 when it turns on. User defined settings
can be stored in file 0 and recalled when AC load turns on. After recalling
factory defaults, file 0 will return to the default settings.
Example 1: (SAVE)
Under CC mode:
1. Press
SAVE
key then pop up a window.
2. Press
0
, then press
ENTER
to save the values in file 0.
S A V E F I L E O F C C M O D E
F I L E = 0
S A V E F I L E = N O
3. Move the cursor by pressing (
◄
,
►
) to the command line of “SAVE FILE =”.
S A V E F I L E O F C C M O D E
F I L E = 0
S A V E F I L E = N O
4. Press the direction key (
◄
,
►
) or rotate the rotary knob to choose “YES”, then press
ENTER
to save file.
S A V E F I L E O F C C M O D E
F I L E = 0
S A V E F I L E = Y E S