5-34
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Section 5: Parts and Module Replacement
5.12.6 Lamp Adjuster Assembly (including IMCB)
(Estimated Replacement Time: 60 m 10 minute LampLOC™ Alignment)
The Lamp Adjuster Assembly is position at the back of the projector directly below the lamp blower and
ducting.
1. Remove lamp door. See
.
2. Remove lamp. See
3. Remove the back cover. See
.
4. Disconnect P35 and P36 from the Lamp Integrated Motor
Control Board.
5. Disconnect the two cathode wires from the cathode nut (one 4
).
6. Remove the three screws located at the base of the lamp blower.
Move the blower assembly to the side to gain access to the two
rear screws holding the lamp adjuster assembly in place
(
7. Loosen the four captive screws, using a #2 Phillips
™
driver, which secure the lamp adjuster assembly to the
baseplate.
8. Remove the lamp adjuster assembly through the lamp door.
Figure 5-47 Cathode Nut
Figure 5-48 Lamp Blower Base
Содержание D4K25
Страница 1: ...D4K25 S e r v i c e M a n u a l 020 100880 01...
Страница 2: ......
Страница 3: ...D4K25 S e r v i c e M a n u a l 020 100880 01...
Страница 10: ......
Страница 18: ......
Страница 30: ......
Страница 52: ......
Страница 92: ......
Страница 93: ...Section 6 Interconnections D4K25 Service Manual 6 3 020 100880 01 Rev 1 06 2012 6 1 D4K25 Interconnect Drawing...
Страница 94: ......
Страница 132: ......
Страница 135: ...Appendix A Exploded Views D4K25 Service Manual A 3 020 100880 01 Rev 1 06 2012 A 1 Exploded View Internal...
Страница 136: ...Appendix A Exploded Views A 4 D4K25 Service Manual 020 100880 01 Rev 1 06 2012 A 2 Exploded View External...
Страница 137: ......