7-8
D4K25 Service Manual
020-100880-01 Rev. 1 (06-2012)
Section 7: Serial API
Start Interrogator, check interrogator status (INT)
SUBCODE
DESCRIPTION OF USE
BASC
Start a basic interrogation (set only)
ENHA
Start an enhanced interrogation (set only)
STAT
Responds with 2 values: currently running (1 if running) and result file.
EXAMPLES:
(INST+BASC 1)
Run a basic interrogation (set only)
(INT+STAT?)
Query interrogator status. Returns (INT+STAT!00100 00000 “Interrogator_Enhanced_20101103194849.7z”),
which means the interrogator is 100% finished, not currently running and the latest interrogator file that was generated is named
“Interrogator_Enhanced_201001103194849.7z” and can be found on the projector’s FTP server.
INTERNAL TEST PATTERN (ITP)
List and select internal test patterns. This command also creates the customized test pattern list from the internal
test patterns. The list of available test patterns is determined by what files are loaded on the TI electronics.
SUBCODE
DESCRIPTION OF USE
FULL
Set(1)/Reset(0) full screen size
KEEP
When KEEP=1, don’t disable test pattern when changing channels
NOCR
NOCR set non-correction test patterns for measured color. Valid range is 0 to 6
NONE
Select test pattern from full list of defined test patterns
STUP
Add test pattern from full list of defined test patterns to the user list
USER
Select test pattern from user defined test pattern list
EXAMPLES:
(ITP ?) Get current test pattern, 0 means no test pattern is used.
(ITP 4) or (ITP “ “) Use number or string to set test pattern
(ITP+USER 4) or (ITP+USER “ “) Use number or string to set test pattern from user’s test pattern list.
(ITP+FULL 1) Use full screen size
(ITP+FULL 0) Use active channel screen file
(ITP+NOCR 1) Set non-correction test patterns for measured color you can use
(ITP+STUP “DC2K Framing Green, DC2K Framing Red”) Add these two test patterns to the user list
(ITP+STUP 1 3) Add these two test patterns indexed in the ITP list to the user list
LAMP INTENSITY CALIBRATION (LCA)
This control is used to calibrate (correlate) the intensity feedback mechanism to footlamberts. Note the minimum/
maximum power are used to pick two points on the curve. These points will not stay consistent over the life of the
lamp, but the conversion algorithm will extrapolate the conversion beyond the range of the two end points. Foot-
lamberts for minimum/maximum power are converted to integer by multiplying 100 because serial command pro-
tocol does not support floating point number.
NOTE
: Changing the lamp or lamp alignment will require re-
calibration.
SUBCODE
DESCRIPTION OF USE
MAXF
Set footlamberts at maximum lamp power, the value should be (footlamberts * 100)
Содержание D4K25
Страница 1: ...D4K25 S e r v i c e M a n u a l 020 100880 01...
Страница 2: ......
Страница 3: ...D4K25 S e r v i c e M a n u a l 020 100880 01...
Страница 10: ......
Страница 18: ......
Страница 30: ......
Страница 52: ......
Страница 92: ......
Страница 93: ...Section 6 Interconnections D4K25 Service Manual 6 3 020 100880 01 Rev 1 06 2012 6 1 D4K25 Interconnect Drawing...
Страница 94: ......
Страница 132: ......
Страница 135: ...Appendix A Exploded Views D4K25 Service Manual A 3 020 100880 01 Rev 1 06 2012 A 1 Exploded View Internal...
Страница 136: ...Appendix A Exploded Views A 4 D4K25 Service Manual 020 100880 01 Rev 1 06 2012 A 2 Exploded View External...
Страница 137: ......