   D4K and Mirage 4K Troubleshooting

D4K and Mirage 4K Troubleshooting Technical Reference

12

020-101452-03 Rev. 1 (10-2014)

The shutter is now in sync.

For details on the serial API commands, refer to the 

D4K Serial API Commands Technical Reference 

(P/N: 020-101258-XX)

 or the 

Mirage 4K Serial API Commands Technical Reference (P/N: 020-

101449-XX)

.

Lamp shuts off when shutter closed

After a Shutter Close command is issued, the lamp shuts off and goes into cool down mode.

Details

The following are potential root causes for the issue:

• The lamp extinguishes due to age. Lamp power is automatically reduced when the shutter is 

closed. Older lamps have difficulty maintaining the arc when the power is too low.

• The projector may be operating out of specification for tilt angle, which can accelerate the aging 

process of the lamp.

• The projector line drawings were not available on the Christie website; therefore, the installers 

may not have been aware of the angle limitations of the projector.

Call log reference number: 421885

Solution

1. To check for an old lamp, reduce lamp power to minimum without closing the shutter and check 

if the lamp automatically extinguish on their own within five minutes. Replace the lamp with a 
new one and check if the problem persists.

2. Ensure the projector tilt is no more than 15 degrees as specified in the lines drawings available 

on the Christie website:

• D4K2560/Mirage 4K25 (P/N: 020-101257-XX)

• D4K3560/Mirage 4K35 (P/N: 020-101256-XX)

Lamp Power Supply Version – Fault Detected 
alarm

The Lamp Power Supply Version – Fault Detected alarm occurred.

Details

No communication is occurring with the lamp power supply. This could occur because the in-line AC 
relay has become disconnected.

Содержание D4K Series

Страница 1: ...D4K and Mirage 4K Troubleshooting Te c h n i c a l R e f e r e n c e 020 101452 03...

Страница 2: ...g Problems or damage caused by improper installation alignment or by equipment modification if by other than Christie service personnel or a Christie authorized repair service provider h Problems or...

Страница 3: ...bol means that electrical and electronic equipment at their end of life should be disposed of separately from regular waste Please dispose of the product appropriately and according to local regulatio...

Страница 4: ...ayPort sources require reset when the projector is power cycled 7 Environmental Board HW Version status item displays Bad Power 8 Green vertical bars in lower right image 9 Dual 3G HD SD SDI Input car...

Страница 5: ...splayPort link connection which results in the graphics card driver dropping the signal Solution The latest AMD driver corrects this issue Contact your video source vendor for an update or download th...

Страница 6: ...ng Incoming signal s problems section in the following manuals D4K2560 User Manual P N 020 101076 XX Mirage 4K25 User Manual P N 020 101361 XX D4K3560 User Manual P N 020 101075 XX Mirage 4K35 User Ma...

Страница 7: ...rong temperature harness is being used for a particular formatter board For more information refer to the following D4K Status System Technical Reference P N 020 101259 XX Mirage 4K Status System Tech...

Страница 8: ...ironmental Board HW Version status item displays Bad Power At startup the Environmental Board HW Version status item displays Bad Power Details The environmental board EVB is not receiving 12V power f...

Страница 9: ...fore any boards are replaced If one or more of the signals are listed as No signal verify that the source is properly configured and the cables are secure between the source and the projector If one o...

Страница 10: ...aged 3G cards Ensure the mating BNC connector pin is not oversized Use 75 ohm connectors not 50 ohm Lamp hours not cleared A new projector does not have the lamp hours factory reset to zero Details St...

Страница 11: ...cting the TPC does not fix the Connection Lost message Power cycling the projector does not solve the problem The user cannot connect using the web page Serial commands using Ethernet RS232 RS422 do n...

Страница 12: ...for tilt angle which can accelerate the aging process of the lamp The projector line drawings were not available on the Christie website therefore the installers may not have been aware of the angle l...

Страница 13: ...oolant is flowing and no Temperature alarms have occurred the Flow Impeded alarm can be ignored as a temporary measure until the root cause for the error is found 4 Do not ignore other system generate...

Страница 14: ...D4K and Mirage 4K Troubleshooting D4K and Mirage 4K Troubleshooting Technical Reference 14 020 101452 03 Rev 1 10 2014 Solution Upgrade to the D4K60 Mirage 4K v1 3 0 software...

Страница 15: ...Seoul ph 82 2 702 1601 Japan Tokyo ph 81 3 3599 7481 India ph 91 080 6708 9999 Germany ph 49 2161 664540 France ph 33 0 1 41 21 44 04 Eastern Europe and Russian Federation ph 36 0 1 47 48 100 China Sh...

Отзывы: