Service setup
H Series Service Manual
17
020-000802-03 Rev. 1 (12-2016)
Adjusting the ROD assembly
To set up for the ROD adjustment, follow the steps below.
1. project an image of 100 inches.
2. Setup in a dark environment <2 Lux.
3. Enter Factory Mode, see
Entering factory mode
on page 9.
4. Select Spoke, select the White Screen test pattern.
5. Adjust the ROD by the screws on the engine module with an M2 socket driver.
6. Adjust screw X followed by screw Y until the yellow or blue image artifacts disappear.
7. If the artifacts do not disappear, adjust screw Z, followed by the X and Y screws.
Adjusting the focus
i
• Avoid over-adjusting the ROD to prevent ROD damage.
• The top cover must be removed during the adjustment.
• Must hold on the interlock switch on the left cover to power on with the top cover
removed.
Warning! Failure to comply with the following could result in death or serious injury.
• Do not see the lamp module to avoid the eyes are injured during the adjustment.
i
If the project image appears fuzzy with the unbalance out of 50cm, perform adjusting the
focus.
Warning! Failure to comply with the following could result in death or serious injury.
• Do not stare into beam when the projector is on. The bright light may result in permanent
eye damage.
1
Test equipment
• A21 standard lens
• Tapeline
• M4 hex key