(BSS 1)
CCA–Color Matching
Defines the hue of each primary color component (red, green, blue, and white).
Commands
Command
Description
Values
CCA+MTRA <0 | 1>
Enables or disables meter adjustments.
0 = Turns off meter adjustments (Default)
1 = Turns on meter adjustments
CCA+MTTP <0 | 1>
Enables or disables the automatic test
patterns for manual adjustment.
0 = Turns off automatic test patterns
1 = Turns on automatic test patterns
(Default)
CCA+RDMI <value>
Specifies the red intensity.
100 to 10000
453 (Default)
CCA+RDMX <value> Specifies the x coordinate for red.
0.300 t0 0.700
0.633 (Default)
CCA+RDMY <value> Specifies the y coordinate for red.
0.300 to 0.500
0.356 (Default)
CCA+GNMI <value>
Specifies the green intensity.
100 to 10000
2137 (Default)
CCA+GNMX <value> Specifies the x coordinate for green.
0.300 to 0.400
0.352 (Default)
CCA+GNMY <value> Specifies the y coordinate for green.
0.400 to 0.700
0.572 (Default)
CCA+BLMI <value>
Specifies the blue intensity.
100 to 10000
239 (Default)
CCA+BLMX <value>
Specifies the x coordinate for blue.
0.100 to 0.300
0.140 (Default)
CCA+BLMY <value>
Specifies the y coordinate for blue.
0.030 to 0.400
0.093 (Default)
CCA+WHMI <value> Specifies the white intensity.
100 to 10000
9219 (Default)
CCA+WHMX <value> Specifies the x coordinate for white.
0.200 to 0.400
0.331 (Default)
CCA+WHMY <value> Specifies the y coordinate for white.
0.200 to 0.400
0.380 (Default)
CCA+RDDG <value> Specifies the red gain.
0.200 to 1.000
Serial API commands