Serial API commands
The GS Series 599 commands can be used to modify product settings.
ADR–Address
Sets or queries the device address.
This command also helps to identify where a response or asynchronous message originates from.
Generally, this command is used for projectors that are daisy-chained together using the RS232 style
communication.
Commands
Command
Description
Values
ADR ?
Checks the current projector address.
(Read-only)
—
ADR <value>
Sets the projector address to <value>.
0 to 9
0 (Default)
Examples
Set the projector address to six:
(ADR 6)
AIM–Auto Image
Reacquires and locks an input signal.
Commands
Command
Description
Values
AIM ?
Checks the current Auto Image
value. (Read-only)
—
AIM <0 | 1>
Reacquires an input signal.
(Write-only)
0 = Normal mode—Supports all 4:3 input sources.
GS Series 599 Serial Commands Technical Reference
10
020-102403-02 Rev. 1 (04-2017)
Copyright
©