(SIN+PORT 5)
(SIN?L)
Result:
(SIN!L001 000 0000 "None")
(SIN!L001 001 0001 "One-Port Dual-Input 3D L:SDI0,R:SDI1")
(SIN!L001 001 0002 "One-Port Dual-Input 3D L:SDI2,R:SDI3")
(SIN!L001 001 0003 "One-Port Dual-Input 3D L:HDMI0,R:HDMI1")
(SIN!L001 001 0004 "One-Port Dual-Input 3D L:DP0,R:DP1")
(SIN!L001 000 0005 "Christie Link [B]")
(SIN!L001 000 0006 "Christie Link [A]")
(SIN!L111 "--END--")
SNM–SNMP Configuration
Configures SNMP support for the projector.
Commands
Command
Description
Values
SNM+LAMP <0 | 1>
Enables or disables light source
faults SNMP trap.
0 = Disables light source faults
1 = Enables light source faults (Default)
SNM+LIFE <0 | 1>
Enables or disables light source
life limit warnings SNMP trap.
0 = Disables light source life limit warnings
1 = Enables light source life limits (Default)
SNM+POWR <0 | 1>
Enables or disables power state
changes SNMP trap.
0 = Disables power state changes
1 = Enables power state changes (Default)
SNM+READ "<name>"
Sets the SNMP Read community
name.
name = String value, maximum 32
characters
Default name = private
SNM+SIGN <0 | 1>
Enables or disables video signal
changes SNMP trap.
0 = Disables video signal changes
1 = Enables video signal changes (Default)
SNM+STAL <0 | 1>
Enables or disables fan/cooling
faults SNMP trap.
0 = Disables fan/cooling faults
1 = Enables fan/cooling faults (Default)
SNM+TIP1 "<IP address>"
SNM+TIP2 "<IP address>"
SNM+TIP3 "<IP address>"
Sets up to three IP addresses for
traps to be sent.
IP address = String value
0.0.0.0 disables notifications (Default)
SNM+THRM <0 | 1>
Enables or disables temperature
faults SNP trap.
0 = Disables temperature faults
1 = Enables temperature faults (Default)
Serial API commands
Christie Technical Reference–Serial Commands
53
020-103316-07 Rev. 1 (09-2022)