CHMER Wire-Cut EDM Operation Manual W5F
1. Analog Voltage Meter
Display the variation of EDM voltage to control machining speed.
2.
Monitor
15”(standard) TFT LCD monitor.
3.
Control panel
a.
Text key: for normal information and number input.
b.
Hot key: control the EDM conditions. (e.g. EDM power supply, dielectric,
wire feed rate and tension)
c.
Function key: system function execution.
4.
Buzzer
Provide warning sound to remind the operator.
5.
EMG-stop button
Under any situation, push this button will cut off power of the controller.
6.
Main Power Switch
Main switch of the CNC controller.
7.
Remote control
Contains basic hot key to operate the machine.
8.
No Fuse Breaker
ON/OFF switch for electric current inflow and overload protection.
9.
CF Card Drive/ USB Card Reader (
Reserved for OPT)
Data storage interface of NC program from external computer. CF memory card or
USB for data storage.
10.
CNC Power ON button
This button is for CNC controller power actuation. After switching on the main
electric power, push this button will actuate the CNC controller. Also, its power
indicator will be on at the same while.
※
Optional Functions (have to confirm controller’s version)
a. Microsoft Mouse / Touch Screen
b. Memory CF Card capability
c. Installing in-house GENTEC Remote Monitoring software enables N.C. file
download /upload, watching on machining status from Client PC through
Internet
1-3