15
Table 2 (continue)
Module type
Dimensions
L*W*H (mm)
Installation method
Fig b & Fig C
Fig d
Fig g
Fig h
Fig e
CHSM6612M
CHSM6612M/HV
CHSM6612P
CHSM6612P/HV
1954*990*40
1954*990*35
+5400Pa
-2400Pa
+5400Pa
-2400Pa
+5400/-2400Pa
Installation scope
299~498mm
---
+2400Pa
-2400Pa
+Bumper
1960*992*40
1960*992*35
+5400Pa
-2400Pa
+5400Pa
-2400Pa
+5400/-2400Pa
Installation scope
299~498mm
---
+2400Pa
-2400Pa
+Bumper
CHSM72M-HC
CHSM72P-HC
CHSM72M/LV-HC
1986*992*40
1986*992*35
+5400Pa
-2400Pa
+5400Pa
-2400Pa
+5400/-2400Pa
Installation scope
315~505mm
---
+2400Pa
-2400Pa
+Bumper
2000*992*40
2000*992*35
+5400Pa
-2400Pa
+5400Pa
-2400Pa
+5400/-2400Pa
Installation scope
315~505mm
---
+2400Pa
-2400Pa
+Bumper
2018*1002*40
2018*1002*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
350±50mm
---
+2400Pa
-2400Pa
+Bumper
2108*1048*35
2094*1038*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
400±50mm
---
+2400Pa
-2400Pa
+Bumper
2256*1133*35
+5400Pa
-2400Pa
+2400Pa
-2400Pa
+5400/-2400Pa
Installation scope
400~450mm
---
+1800Pa
-1800Pa
+Bumper
6
Electrical Installation
6.1
Electrical properties
For details of the electrical performance
parameters of Chint Solar PV modules, please refer to
the PV module product manual.
Rated electrical characteristics such as Isc is
within
±
5% and Voc within
±
3% and Pmpp within
±
3% of tolerance values at Standard Test Conditions.
Standard Test Conditions: 1000W/m2 Irradiance, 25
℃
Cell Temperature and 1.5 Air Mass.
The IEC & UL standard maximum system
voltage for the regular module series is 1000V, the
1500V standard products are also available according
to the requirements. The IEC & UL standard