In addition to the above considerations we recommend an air vent in any small
sealed structure such a shepherds hut, garden shed/office placed at both high or low
level. This is a provision for combustion air in small spaces and a carbon monoxide
precaution. It should be in a position that it cannot easily be blocked. Vents should be
positioned as close as possible to the stove, at least 300mm away from the chimney or
other flue outlet.
3.g
Ventilation - Glamping or Leisure Accommodation
•
In order for a stove to operate correctly there needs to be sufficient combustion air
•
For stoves of 5 kW and under such as the Chilli Billie a permanently open vent is
sometimes required, usually in new build houses and extensions. This can depend
on the air permeability (air leakage) of your property. Your HETAS installer should
be able to guide you.
•
The general principle is 550mm
2
of ventilation per kW output of stove.
•
Confirmation of the amount of ventilation can be verified with a smoke spillage test.
•
In addition a stove
should not
be fitted in a room with an appliance such as
extractor fan, ceiling fan or tumble drier, it will affect the draw of the stove and
could lead to fumes entering the room.
•
All air vents should be positioned so that thay are not liable to blockage
3.f
Ventilation - Domestic Installations
3.e
Siting and Escape Routes - Domestic/Glamping & Leisure
The siting of your Chilli Billie must not be in a position that will block or inhibit exit from
the accommodation in an emergency. It must not increase the risk of ignition to the
fabric of the accommodation, whether domestic or leisure.
Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas
have been “authorised” in Regulations and that appliances used to burn solid fuel in
those areas (other than “authorised” fuels) have been exempted by an Order made and
signed by the Secretary of State or Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found here:
www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including
designation and supervision of smoke control areas and you can contact them for
details of Clean Air Act requirements.
The Chilli Billie with smoke control adaptation has been tested as suitable for use in
smoke control areas, it is awaiting certification.
Page 14 of 43
Содержание Chilli Billie
Страница 1: ...www chillipenguin co uk CSP 9768 11 2020 Installation and Operating Manual The Chilli Billie...
Страница 2: ...Thelittlestove withabigheart The Chilli Billie Wood only St f Fach Gyda Chalon Fawr...
Страница 8: ...Theplans technicaldetails Page 06 10 Section 2 Page 06 of 43...
Страница 13: ...Installation instructions Page 11 24 Section 3 Page 11 of 43 www chillipenguin co uk...
Страница 27: ...Instructionsforuse Page 25 31 Section 4 Page 11 of 43 www chillipenguin co uk...
Страница 34: ...Maintenance Page 32 39 Section 5 Page 32 of 43...
Страница 42: ...Page 40 43 Efficiency CElabels Guarantee Section 6 Page 40 of 43...