3.
Installation Instructions
All local and national regulations must be observed when installing the appliance. If
installed incorrectly serious accidents can be caused.
BUILDING REGULATION REQUIREMENTS (DOMESTIC)
Building Regulation Document J must be refered to when installing this appliance.It is
the installers responsibility to ensure the manufacturers instructions are complied with.
A HETAS qualified installation engineer should carry out the installation and issue a
compliance certificate or alternatively your local Building control department needs to
inspect the installation and register the work carried out.
3.a
Domestic Installations (In Houses) - Warning
There has been a growth in the use of woodburning stoves in glamping, leisure and
small space accommodation, such as shepherds huts, wooden pods, yurts and safari
tents. We recommend that you fit a Chilli Billie in any structure to the same standards
that you would in a house. The risks are the same, if not greater in a small space.
Combustible surfaces are likely to be closer, so it needs careful design consideration in
the planning stage.
We believe that there are additional risks in canvas structures e.g. yurts, teepees and
safari tents. Adverse weather can cause movement of the surface the flue is exiting
through. The surfaces of some structures e.g. a yurt may be flamable. The flashing must
allow for some movement and the stove, enclosure and each section of flue should be
mechanically fixed to each other and the hearth to prevent smoke spillage under these
circumstances.
We recommend that you be guided by the principle of taking all and every
reasonable precaution to protect and preserve safety. This is of particular importance
if these structures are used for holiday/event rental as the users can be unfamiliar
with wood burning stoves and any risks factors that a single, regular user might be
sensitive to.
3.b
Installations (Glamping/Leisure Accommodation) - Warning
BUILDING REGULATION REQUIREMENTS (GLAMPING/LEISURE)
Although the regulatory requirements currently stipulate that leisure accommodation
units fall outside the remit of Schedule 2 of the UK Building Regulations, installers
should always ensure under their responsibilities as a competent engineer that
installations are done in a manner that is deemed safe, and meet the fundamental
safety and efficiency requirements as laid out in regulations J1 to J5 of Approved
Document J where practical. Page 9 of ADJ sets the legal precedents as follows:
J1 Air Supply:
Combustion appliances shall be so installed that there is an adequate
supply of air to them for combustion, to prevent overheating and for the efficient
working of the flue.
Page 12 of 43
Содержание Chilli Billie
Страница 1: ...www chillipenguin co uk CSP 9768 11 2020 Installation and Operating Manual The Chilli Billie...
Страница 2: ...Thelittlestove withabigheart The Chilli Billie Wood only St f Fach Gyda Chalon Fawr...
Страница 8: ...Theplans technicaldetails Page 06 10 Section 2 Page 06 of 43...
Страница 13: ...Installation instructions Page 11 24 Section 3 Page 11 of 43 www chillipenguin co uk...
Страница 27: ...Instructionsforuse Page 25 31 Section 4 Page 11 of 43 www chillipenguin co uk...
Страница 34: ...Maintenance Page 32 39 Section 5 Page 32 of 43...
Страница 42: ...Page 40 43 Efficiency CElabels Guarantee Section 6 Page 40 of 43...