![Chigo CCA-18HR1 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/chigo/cca-18hr1/cca-18hr1_technical-manual_2601241062.webp)
R410A50Hz Universal Outdoor Series Technical Manual Duct Type Indoor Unit
59
GD Chigo Heating & Ventilation Equipment Co., Ltd.
6.16 CTB-36HR1
MODEL
CTB-36HR1
HEATING
OUTDOOR CONDITIONS
Indoor Conditions
24ºC DB
18ºC WB
12ºC DB
11ºC WB
7ºC DB
6ºC WB
4ºC DB
3ºC WB
0ºC DB
-1ºC WB
-5ºC DB
-6ºC WB
-7ºC DB
-8ºC WB
15ºC
Capacity kW
19.16
15.35
12.76
11.46
10.83
9.55
8.92
Input kW.
6.32
5.11
4.22
4.03
3.77
3.62
3.4
18ºC
Capacity kW
17.87
14.33
11.89
10.74
10.17
9.03
8.37
Input kW.
6
4.76
3.98
3.78
3.58
3.37
3.19
20ºC
Capacity kW
16.62
13.29
11.55
9.89
9.48
8.31
7.73
Input kW.
5.38
4.26
3.42
3.31
3.18
3.08
2.92
22ºC
Capacity kW
15.28
12.26
10.24
9.12
8.66
7.62
7.11
Input kW.
5.08
4.08
3.39
3.17
3.04
2.87
2.72
27ºC
Capacity kW
13.3
10.62
8.86
8.03
7.53
6.62
6.2
Input kW.
4.36
3.52
2.95
2.81
2.62
2.49
2.36
6.17 CTB-48HR1
MODEL
CTB-48HR1
HEATING
OUTDOOR CONDITIONS
Indoor Conditions
24ºC DB
18ºC WB
12ºC DB
11ºC WB
7ºC DB
6ºC WB
4ºC DB
3ºC WB
0ºC DB
-1ºC WB
-5ºC DB
-6ºC WB
-7ºC DB
-8ºC WB
15ºC
Capacity kW
26.18
20.96
17.46
15.71
14.84
13.09
12.22
Input kW.
8.56
6.87
5.72
5.43
5.14
4.86
4.59
18ºC
Capacity kW
24.57
19.66
16.4
14.73
13.91
12.29
11.47
Input kW.
8.12
6.43
5.37
5.12
4.86
4.59
4.31
20ºC
Capacity kW
22.65
18.15
15.20
13.54
12.88
11.28
10.59
Input kW.
7.46
5.97
5.42
4.98
4.72
4.35
4.14
22ºC
Capacity kW
20.92
16.74
13.96
12.54
11.85
10.45
9.76
Input kW.
6.85
5.52
4.63
4.38
4.14
3.89
3.72
27ºC
Capacity kW
18.21
14.52
12.14
10.89
10.31
9.1
8.49
Input kW.
5.96
4.82
3.99
3.81
3.64
3.42
3.22
6.18 CTB-60HR1
MODEL
CTB-60HR1
HEATING
OUTDOOR CONDITIONS
Indoor Conditions
24ºC DB
18ºC WB
12ºC DB
11ºC WB
7ºC DB
6ºC WB
4ºC DB
3ºC WB
0ºC DB
-1ºC WB
-5ºC DB
-6ºC WB
-7ºC DB
-8ºC WB
15ºC
Capacity kW
30.36
24.25
20.24
18.24
17.21
15.21
14.17
Input kW.
10.31
8.24
6.88
6.54
6.19
5.85
5.51
18ºC
Capacity kW
28.51
22.81
19.12
17.16
16.17
14.26
13.31
Input kW.
9.72
7.81
6.52
6.14
5.82
5.5
5.16
20ºC
Capacity kW
26.4
21.14
17.6
15.84
15.02
13.24
12.32
Input kW.
8.95
7.18
6.09
5.66
5.38
5.06
4.81
22ºC
Capacity kW
24.32
19.4
16.2
14.58
13.76
12.15
11.34
Input kW.
8.3
6.59
5.5
5.22
4.93
4.67
4.4
27ºC
Capacity kW
21.14
16.92
14.12
12.68
11.98
10.62
9.88
Input kW.
7.18
5.74
4.78
4.54
4.34
4.05
3.82
6.19 CTB-48HR1-B
MODEL
CTB-48HR1-B
HEATING
OUTDOOR CONDITIONS
Indoor Conditions
24ºC DB
18ºC WB
12ºC DB
11ºC WB
7ºC DB
6ºC WB
4ºC DB
3ºC WB
0ºC DB
-1ºC WB
-5ºC DB
-6ºC WB
-7ºC DB
-8ºC WB
15ºC
Capacity kW
25.10
20.45
16.33
15.54
14.82
13.34
12.03
Input kW.
8.43
6.56
5.45
5.23
5.04
4.67
4.45
18ºC
Capacity kW
23.37
19.34
16.21
14.35
13.77
12.02
11.23
Input kW.
8.09
6.34
5.11
5.01
4.83
4.49
4.21
20ºC
Capacity kW
22.22
17.19
15.17
13.38
12.71
11.03
10.48
Input kW.
7.24
5.87
5.41
4.72
4.55
4.37
4.13
22ºC
Capacity kW
19.92
15.79
13.55
12.34
11.66
10.92
9.70
Input kW.
6.84
5.51
4.68
4.45
4.03
3.76
3.49
27ºC
Capacity kW
17.23
14.50
12.22
10.77
10.34
9.10
8.38
Input kW.
5.96
4.81
3.98
3.77
3.60
3.22
3.27