R410A50Hz Universal Outdoor Series Technical Manual control
126
GD Chigo Heating & Ventilation Equipment Co., Ltd.
B. MODE key:
Press the key to switch modes in the order: automatic cooling →dehumidify →heating →ventilating
→automatic.
C.
"
▼
"
key:
In dehumidifying mode and automatic mode, pressing the key cannot change the temperature. In
other mode, press the key once and the temperature will decrease 1
℃
in the order: 32
℃
→31
℃
→…→17
℃
→16
℃
.
D.
"
▲
"
key:
In dehumidifying mode and automatic mode, pressing the key cannot change the temperature. In
other mode, press the key once and the temperature will increase 1
℃
in the order: 16
℃
→17
℃
→…→31
℃
→32
℃
.
E. SWING key:
In dehumidifying mode, the swing mode is in the stable wind mode without change. In other mode,
press the key to switch modes in the order: swing → stable wind→ natural wind →swing
F. AIR FLOW key:
The default air flow is in the swing mode when starting firstly and press the key to switch modes in
the order: swing →stop →swing.
G. WIND SPEED key:
The default wind speed is in the automatic wind mode when starting firstly. The remote control
won
'
t react by pressing the key because the wind speed can’t be adjusted and in low speed in
dehumidifying mode. In other mode, press the key to switch modes in the order:
Automatic wind→ high speed →middle speed→ low speed →automatic wind
H. TIMER key:
The default mode is in no timing state, press the key to set timing time with hour as its union. The
switch order is: 1H→2H→…→24H→cancel→1H…. Press the key to set timing starting in the off
state and set timing stopping in the on state. After setting timing function, the time keeps
decreasing per hour until the time decreasing to the timing on or timing off and the timing display
will be cancelled at the same time. Pressing MODE key can’t cancel timing in timing mode which
will send out the order of timing time by pressing other key.
I. TURBO key: